EN
EN - 17 -
6.1.5 Optics
The cleaning of optical parts (lenses) shall be carried out with solutions containing alcohol.
6.1.6 Analysis
If there is still a problem after the troubleshooting procedures (Cf. section 7),
contact RJ distributor with the following information:
• Model, version and serial number of the product.
• Software version (available in menu Fixture Status
→
Version)
• Description of the problem.
6.1.7 LED reaction according to LED temperature
LED intensity dims to zero output (overheating protection).
DMX and system LED feedback (7) is red and temperature is available in
Fixture Status menu.
6.1.8 Thermal protection
In case of thermal protection start :
• Remove the LED compartment (Cf.
6.1.4
).
• Control possible overheating indications.
• Reassemble the LED compartment.
• Reset the thermal protection by pressing the button.
6.1.9 Adjusting the maximum light output level
The maximum intensity level of the LED source can be adjusted through the fixture setup
in order to have a consistent fixture fleet. The dimming level is then recalculated depending
on the limitation.
6.1.10 Exploded view / Spare parts list
⇒
Available on
www.robertjuliat.com
⇒
Or on request through the
Robert Juliat
Service department
Lens tube access
LED temperature
Fan
5°C
→
65°C
Fan rotation at minimum level
65°C
→
75°C
Fan rotation increases progressively
75°C
→
90°C
Fan at maximum speed
LED intensity dims to zero output
(overheating protection)
DMX and system LED feedback (7) is red