EN
EN - 16 -
5.1.4 Reset
• Reset to default settings:
Menu:
Fixture
Reset
→
press
Select
→
Yes & press
Select
to validate
5.1.5 Feedback information
• DMX and system LED feedback (see
display & controls
7
, Cf.
EN-15
):
⇒
Green= DMX512 frame detected
⇒
Red = Problem on DMX512 frame and/or system default – details available in the fixture status
•
If DMX512 data lost, the following message is displayed:
“Push select to reset DMX values”
The last received DMX values are stored but it is possible to inactivate the current values
by pressing the Select key (as well as the Master function) in order to get a total control of
the fixture locally. When a DMX signal is detected, the DMX control is active again.
• ¥ signal indicates a wireless DMX:
Signal
Information
Switched off – no symbol
The fixture is not paired with a transmitter
Slow intermittent display
The fixture is paired with a transmitter but the DMX signal is not
detected
Continuous display
The fixture is paired with a transmitter and the DMX signal is
detected
Rapid intermittent display
Lost connection with the transmitter or in connection with the
transmitter
6 Service
6.1 Preventive maintenance
6.1.1 Frequency
General maintenance should be performed at least once a year or more frequently if
the equipment is operated in adverse conditions (smoke, heat, humidity, touring, etc.).
6.1.2 General cleaning
Remove dust from the unit (air vents, printed circuit boards, etc.).
During cleaning:
•
• LED is protected by a safety glass to avoid any contact.
DO NOT spray directly onto the glass.
•
• Fan blades must be locked.
6.1.3 General visual check
• No trace of heat.
• No loose contacts.
• No missing parts.
• Tighten mechanical assemblies (screws, bolts and nuts, ground connections, etc.).
6.1.4 LED source
• Do not touch the surface of the LED source
(
no contact with your hands or any tools
).
• Do not put compressed air directly on the source.
• Contact a certified RJ distributor in case of residuals or other objects located on
the surface of the LED source.