background image

1149B - SUPER KORRIGAN

• 

1449B - LUCY

• 

1159B - VICTOR

• 

1459B - FLO

• 

DMX-CONTROL OF MOTORISED DIMMER

SHUTTER AND LAMP IGNITION

DN40974701

RJ NET

FOR COMPACT FOLLOWSPOT RANGE

Robert Juliat S.A.S.  Route de Beaumont,  F 60530 Fresnoy-en-Thelle  -  phone : +33 (0)3 44 26 51 89 - fax : +33 (0)3 44 26 90 79 - [email protected]

Robert Juliat U.S.A.  48 Capital Drive, Wallingford, CT 06492  -  phone : (203) 294 0481 - fax : (203) 294 0482 - [email protected]

Manual

Product version :

- "LUCY" 1449 : V3
- "SUPER KORRIGAN" 1149 : V3
- 'FLO" 1459 : V3
- "VICTOR" 1159 : V4

Software version :

- Dimmer card : V1-03
- Control Board card : V1-06

VALIDATION : 01/01/10

Summary of Contents for Lucy 1449B

Page 1: ...aumont F 60530 Fresnoy en Thelle phone 33 0 3 44 26 51 89 fax 33 0 3 44 26 90 79 info robertjuliat fr Robert Juliat U S A 48 Capital Drive Wallingford CT 06492 phone 203 294 0481 fax 203 294 0482 info...

Page 2: ...6 4 2 3 Emergency mode 7 4 3 RJNET control board 7 4 3 1 Display and controls 7 4 3 2 Menus and parameters 8 4 3 3 Feedback information 10 4 4 Remote control by DMX protocol 11 5 Service 12 5 1 Preven...

Page 3: ...inema and photograph studios Standards NF EN 60598 1 and NF EN60598 2 17 4 This fixture is rated as IP20 and is for indoor use only SERVICE 1 These fixtures must only be serviced by a qualified techni...

Page 4: ...rd 2 Dimmer local control 3 Followspot power connector 4 Data and accessories connectors 5 PSU Lamp hour counter 6 PSU lamp switch 7 PSU mains LED 8 PSU mains breaker 9 PSU power connector 10 PSU lamp...

Page 5: ...To control the dimmer from the followspot location Followspots CONTROL BOARD RJNET Dimmer Dimmer local control DMX Passes Through the Module No data conversion faster transmission Module continues to...

Page 6: ...is XLR 7 pin XLR 5 pin Description for DMX XLR 7 pin Description for external RJBUS Accessories Cable identification Cable identification Power Conductor Power Conductor Power Conductor Colour cable b...

Page 7: ...to the RJBUS connector Switch has to be on dimmer position to operate from the PF1CAN 3 3 2 Scroller colour changers 24Volt DMX controlled accessories like scroller colour changers can be connected t...

Page 8: ...1 3 Lamp strike counter Number of strikes of the lamp ignition is given by the RJNET control board in the TEST menu cf 4 3 2 4 2 Dimmer shutter 4 2 1 Control Dimmer shutter light intensity can be cont...

Page 9: ...information do tests and adjusts local values 4 3 1 Display and controls Main view activated after 5 seconds of inactivity Lamp Sun ON Moon OFF Dimmer level bargraph Dimmer value If flickering Value...

Page 10: ...l 0 0 1 Value Function 1 512 DMX address P o w e r U p M o d e O F F P o w e r U p M o d e O F F Value Function OFF Manual ignition ON Automatic ignition D M X P a t c h O F F D M X P a t c h O F F Va...

Page 11: ...n 1 512 Followspot DMX address M c o n t r l 0 0 1 L p O F F C h a n n e l 0 d 0 0 h Value Function OFF Lamp OFF ON Lamp ignition see 4 1 D i m m e r 0 0 2 0 0 3 0 0 4 O n s t a g e 0 d 0 d 0 d D i m...

Page 12: ...ct to reset DMX values By pushing select DMX values will be deactivated until DMX comes back so local control values local control handle RJNET P1FCAN will control the module from 0 to 100 Master cont...

Page 13: ...ton pressed Details and reset can be done from the MODULE PARAMETERS menu or by DMX 4 4 Remote control by DMX protocol D i m m e r 0 0 2 0 0 3 0 0 4 O n s t a g e 0 d 0 d 0 d Highest command Feedback...

Page 14: ...e of heat No loose contacts No missing parts Tighten mechanical assemblies screws bolts and nuts ground connections etc 5 1 4 Wiring Connections Cable terminal screw Visually check tighten if necessar...

Page 15: ...ct 5 1 7 Shutter limit stop Remove dust from shutter limit stops 5 2 Analyse In there is still a problem after the Troubleshooting procedures Cf 6 contact RJ distributor with the following information...

Page 16: ...JNET control board DMX value sent by DMX Check DMX address of the 1st channel in FIXTURE PARAMETERS menu Disable DMX Patch function I FIXTURE PARAMETERS menu Disconnect DMX and push select to reset DM...

Reviews: