background image

- 2 -

2   Presentation

 2.1  RJNET

 2.2 

 

Optional 

accessories

Functions :

Reference

Description

1.   RJNET control board
2.   Dimmer local control
3.   Followspot power connector
4.   Data and accessories connectors

5.   PSU Lamp hour counter
6.   PSU lamp switch 
7.   PSU mains LED
8.   PSU mains breaker
9.   PSU power connector
10.  PSU lamp on LED

1   P1FCAN  

Dimmer remote control for RJNET

2   Contact RJ   215x215mm gel frame holder for scroller

1

Summary of Contents for Lucy 1449B

Page 1: ...aumont F 60530 Fresnoy en Thelle phone 33 0 3 44 26 51 89 fax 33 0 3 44 26 90 79 info robertjuliat fr Robert Juliat U S A 48 Capital Drive Wallingford CT 06492 phone 203 294 0481 fax 203 294 0482 info...

Page 2: ...6 4 2 3 Emergency mode 7 4 3 RJNET control board 7 4 3 1 Display and controls 7 4 3 2 Menus and parameters 8 4 3 3 Feedback information 10 4 4 Remote control by DMX protocol 11 5 Service 12 5 1 Preven...

Page 3: ...inema and photograph studios Standards NF EN 60598 1 and NF EN60598 2 17 4 This fixture is rated as IP20 and is for indoor use only SERVICE 1 These fixtures must only be serviced by a qualified techni...

Page 4: ...rd 2 Dimmer local control 3 Followspot power connector 4 Data and accessories connectors 5 PSU Lamp hour counter 6 PSU lamp switch 7 PSU mains LED 8 PSU mains breaker 9 PSU power connector 10 PSU lamp...

Page 5: ...To control the dimmer from the followspot location Followspots CONTROL BOARD RJNET Dimmer Dimmer local control DMX Passes Through the Module No data conversion faster transmission Module continues to...

Page 6: ...is XLR 7 pin XLR 5 pin Description for DMX XLR 7 pin Description for external RJBUS Accessories Cable identification Cable identification Power Conductor Power Conductor Power Conductor Colour cable b...

Page 7: ...to the RJBUS connector Switch has to be on dimmer position to operate from the PF1CAN 3 3 2 Scroller colour changers 24Volt DMX controlled accessories like scroller colour changers can be connected t...

Page 8: ...1 3 Lamp strike counter Number of strikes of the lamp ignition is given by the RJNET control board in the TEST menu cf 4 3 2 4 2 Dimmer shutter 4 2 1 Control Dimmer shutter light intensity can be cont...

Page 9: ...information do tests and adjusts local values 4 3 1 Display and controls Main view activated after 5 seconds of inactivity Lamp Sun ON Moon OFF Dimmer level bargraph Dimmer value If flickering Value...

Page 10: ...l 0 0 1 Value Function 1 512 DMX address P o w e r U p M o d e O F F P o w e r U p M o d e O F F Value Function OFF Manual ignition ON Automatic ignition D M X P a t c h O F F D M X P a t c h O F F Va...

Page 11: ...n 1 512 Followspot DMX address M c o n t r l 0 0 1 L p O F F C h a n n e l 0 d 0 0 h Value Function OFF Lamp OFF ON Lamp ignition see 4 1 D i m m e r 0 0 2 0 0 3 0 0 4 O n s t a g e 0 d 0 d 0 d D i m...

Page 12: ...ct to reset DMX values By pushing select DMX values will be deactivated until DMX comes back so local control values local control handle RJNET P1FCAN will control the module from 0 to 100 Master cont...

Page 13: ...ton pressed Details and reset can be done from the MODULE PARAMETERS menu or by DMX 4 4 Remote control by DMX protocol D i m m e r 0 0 2 0 0 3 0 0 4 O n s t a g e 0 d 0 d 0 d Highest command Feedback...

Page 14: ...e of heat No loose contacts No missing parts Tighten mechanical assemblies screws bolts and nuts ground connections etc 5 1 4 Wiring Connections Cable terminal screw Visually check tighten if necessar...

Page 15: ...ct 5 1 7 Shutter limit stop Remove dust from shutter limit stops 5 2 Analyse In there is still a problem after the Troubleshooting procedures Cf 6 contact RJ distributor with the following information...

Page 16: ...JNET control board DMX value sent by DMX Check DMX address of the 1st channel in FIXTURE PARAMETERS menu Disable DMX Patch function I FIXTURE PARAMETERS menu Disconnect DMX and push select to reset DM...