TROUBLE SHOOTING.
OPERATION
SYMPTOMS
POSSIBLE CAUSES
SOLUTIONS
THE POWER
SUPPLY UNIT (PSU)
1200W
1800W
1 Mains checklight.
2 "ON-OFF" switch.
3 Lamp ON,
checklight.
4 Fuse
No light coming
through the
lamp house.
Checklight 1 does
not light up when the
power supply unit is
connected.
The checklight 3 does
not light up when 1
is on.
Hard striking on.
No power.
The switch is OFF.
Circuit breaker and
transformer are OFF.
Check the Spark-gap.
Check the mains and
cable conne
electrical diagram,
refer to pages A - 5 & C - 23.
Repeat the operation,
refer to page A - 7.
Turn ON the circuit
breakers, refer to page A - 7.
Bad contact. Harting plug
power supply / Head.
Side trapdoors are not
closed.
Check the connections,
refer to page A - 5.
Make sure the doors are
properly closed. Adjust the
position of the mini-circuit
breaker.
Lamp is badly mounted.
Ignition failure.
(igniter, Spark-gap).
Open colour unit at the
front of the lighting unit.
Colour changer unit
closed.
Iris cassette closed.
Refer to page A - 5.
Mirrors and lenses not
in right condition or
not in place.
fan is not working.
No ventilation from the lamp house.
Premature deterioration of the filter
Bad quality light beam.
No light in the lens tube.
(lamp house lit).
No light coming through the lamp house.
HEAD
(Checklight 3 off).
(Checklight 3 on).
HEAD
Refer to page B - 1.
Check iris blades are open
when turning the handle.
Refer to page B - 1.
Refer to page A - 7.
Refer to page B - 1.
The lamp doesn’t light
up.
Fuse blown out.
Change the fuse 5 .
Refer to page A - 5
WARNING :
Do not use the lighting unit if the fan is not working.
(Note: The fan doesn't work until the lamp and checklight 3 are ON.)
2
3
3
2
1
1
4
30.23
LAMP ON
ON
TELECOMMANDE /
REMOTE CONTROL
AMONT
MAINS
FUSE
OFF
HMI 1200
220/240V 50Hz
- No HT* gel inserted.
- Infra-Red filter not engaged.
- Insert HT* gel.
- Engage Infra-Red filter.
(*) Place the darker colours in front. HT = High temperature resistance