robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
Robert Juliat reserve the right to change or alter any of the items detailed on this page, to increase or improve manufacturing techniques without prior notice.
VALID SINCE
: 09.05.01
DocT
ech1039_1439_090501.ind
12
TECHNICAL FILE
2500W HMI FOLLOW SPOT
A 1039/1439 Manual shutter version.
d
- EM HARTING 16 x 16A power socket.
e
- 10A. 250V. EEC - Female mains socket.
B Power supply unit.
1
- Mains checklight.
2
- UNI + N 2A-C automatic breaker.
3
- General 25A automatic breaker.
4
- UNI + N 2A-C automatic breaker.
6
- Ventilation opening
(DON'T OBSTRUCT THE AIR GAPS).
7
- EF HARTING 16 x 16A - 2 latch connector.
8
- Mains cable 3 x 4 mm
2
(3m)+P17 32A+E plug.
9
- Lamp ON, checklight.
10
- "ON/OFF" switch.
When the switch is ON and the checklight is OFF,
the lighting of the HMI lamp has failed.
Repeat the operation.
11
- Rating plate.
12
-
External control
by a straight closing contact (1A - 250V).
13
- Power supply selector :
208V. 60Hz, 230V. 50Hz & 245V. 50Hz.
Position locked by a screw.
C Lamp cable.
Cable H07 RN-F 19G1,5 mm
2
length 3m fitted
with 16 x 16A M/F HARTING connectors.
Lighting unit / Power supply connection.
- Connect the lamp cable C to the connector 7 of the
ballast and connector d to the lighting unit.
- Lock the cable C into the cable lock f .
- Place the lamp into position - refer to page 16.
- Engage the automatic breaker 3 and check that the protection
4 is well engaged.
- Plug the cable 8 to the mains. If the power is present, the
checklight 1 lights up immediately.
- Engage the automatic breaker 2 .
WARNING !
- Never open the lantern's bonnet when the lighting unit is on.
- Do not change the safety switches.
- Never connect to a dimmable channel.
- Use only when lamp in place.
DESCRIPTION.
Mains voltage.
- Check the conformity of the power supply unit.
Rating plate 11 : Lamp power.
Power supply unit
(P.S.U.)
B
d
A
C
DIMMER
WARNING
:
DO NOT
TRANSPORT
THIS LANTE
RN WITH
LAMP INSID
E.
ATTENTION
:
NE PAS TR
ANSPORTER
LE
PROJECTEUR
AVEC LA LA
MPE MONTEE.
220V. 2A.
COLOR CHA
NGER
SOCKET
LOCKING
SERRAGE
DOUILLE
e
CONNECTIONS.
1039 & 1439
f
Summary of Contents for 1039
Page 2: ...NOTES ...