Robe Stage Banner 10 AT Series User Manual Download Page 18

18

19

Note1

:Software update should execute a qualified person.If you lack qualification, do not attempt the update

yourself and ask for help your ROBE distributor.

Note 2

:DMX address, IP address ,programs 1-3 and all functions in menu "PErS" will be set to their default 

values.

To update software in the fixture:

1

.Installation of DMX Software Uploader.

 

1.

DMX Software Uploader  program is available from the ROBE web site at WWW.robe.cz.

 

2

.Make a new directory ( e.g. Robe_Uploader) on your hard disk and download the software to it. 

 

3

.Unpack the program from the archive. If the Robe fixture is produced in magnetic and electronic

 

 ballast version, name of DMX Software Uploader is the same for both versions.

2.

Fixture software updating.

 

1

.Determine which of your COM port is available on your PC and connect it with to the DMX input

 

 of the fixture using the uploading cable. Do not extend this cable! Disconnect the fixture from the  

 

other fixtures in DMX chain! Turn on the computer and  the fixture. 

 

2

.Switch the fixture to the update mode by selecting the option Updating mode in menu Special

 

 Functions on the fixture control panel:SPEC-->UPd-->yES.(From this option you cannot return back  

 

to the main menu. If you do not want to continue in software update, you have to switch off  and on  

 

the fixture to leave this option!)

 

3

.It is recommended that you exit all programs before running the Software Uploader.

 

4

.Start the Software Uploader program. Select desired COM and then click Connect button.

 

If the conection is OK, click Start Uploading button to start uploading. It will take several minutes to

 

 perform software update. If the option "Incremental Update"isn´t checked ,all processors will be 

 

updated (including  processors with the same software version). 

 

If you wish to update only later versions of processors, enable the Incremental Update check box.

 

Avoid interrupting the process. Update status is being displayed in the list window.

 

When the update is finished, the line with the text “The fixture is successfuly updated‘ will appear in

 

 this window and the fixture will reset with the new software.

Note: In the case of  interruption of the upload process (e.g. power cut), the fixture remains in the update mode 

and you have to repeat the software update again.

For example: The fixture was switched off before finishing software upload. After switching the fixture on again, 

the fixture is still in the update mode and the display is dark. Restart the Software Uploader program and repeat 

software update from your PC.

9. Low power mode

This mode omits fixture reset after switching the fixture on and lowers motor powers of the fixture."Power down 

mode" is useful in special cases,e.g. if the fixture is in a flight case and you want to set its DMX address  without 

taking it out from the case.To enter "Power down mode",press and hold [UP] and [DOWN] and at the same time 

switch on the Power switch.The following message appears on the display:

"P.d.Mo."

Press [ENTER] to activate "Low power mode" without fixture reset.Now you can set features and behaviour 

of the fixture by using "

A001

" and 

"Pers.

" menu.If you want to go to the "normal operation mode",execute a 

fixture reset.

Summary of Contents for Stage Banner 10 AT Series

Page 1: ...1 Version 1 1 ...

Page 2: ... 10 AT DMX Protocol version 1 0 10 6 Operating modes 11 6 1 Controller mode 11 6 2 Stand alone mode 11 7 Control menu map 12 8 Control menu 14 8 1 Fixture Address 14 8 2 Slave control 14 8 3 Fixture informations 14 8 4 Personality 15 8 5 Manual mode 16 8 6 Test sequences 16 8 7 Stand alone setting 16 8 8 Reset function 17 8 9 Special functions 17 9 Low power mode 18 10 Error and information messag...

Page 3: ... to the device are not subject to warranty Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Make sure that the available voltage is not higher than stated on the rear panel Always plug in the power plug least Make sure that the power switch is set to Off position before you connect the device to the mains ...

Page 4: ...place is blocked when rigging derigging or servicing the fix ture Always fix the fixture with an appropriate safety rope Fix the safety rope at the correct holes only Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fas tened The maximum ambient temperature 45 C must never be exceeded Operate the device only after having familiarized with i...

Page 5: ... Rotating plate 4 Top covers Rear panel of the fixture 5 Power switch 6 Power cord 7 Fuse holder 8 3 pin DMX output 9 3 pin DMX input 10 5 pin DMX output 11 5 pin DMX input Front panel of the fixture 12 Mode button 13 Enter button 14 Up button 15 Down button 16 Display ...

Page 6: ... US Pin International Brown Black Live L Light blue White Neutral N Yellow Green Green Earth 4 2 Changing the power supply settings Both the transformer and the ballast must be connected correctly for the local AC voltage and frequency The wrong settings can cause poor performance or demage of the fixture The factory settings are printed next to the power switch If you want to change the power sup...

Page 7: ...all installation material and the device If you lack these qualifications do not attempt the installation yourself but instead use a professional structural rigger Improper installation can result in bodily injury and or damage to property The device has to be installed out of the reach of people If the device shall be lowered from the ceiling or high joists professional trussing systems have to b...

Page 8: ... holders on the bottom of the base by inserting both quick lock fasteners 3 into the holes of the base and tighten fully clockwise 3 Fasten the safety cable 2 through the two apertures on the bottom of the base and over the trussing sys tem 1 Clamp 2 Safety cable 3 Quick lock fastener 4 Omega holder advertising plate Omega holder safety cable fixing clamp clamp rotating plate ...

Page 9: ... the DMX chain with the DMX input of the next fixture Always connect one output with the input of the next fixture until all fixtures are connected Caution At the last fixture the DMX cable has to be terminated with a terminator Solder a 120 Ω resistor between Signal and Signal into a 3 pin XLR plug and plug it in the DMX output of the last fixture Building a master slave chain Connect the DMX out...

Page 10: ...from 0 1 s to 25 5 s step proportional proportional 4 0 129 130 139 140 199 200 255 Pan functions Standard operation fixture is controlled by channels 1 2 and 3 Reset of the pan Forward pan rotation speed is controlled by channel 3 Backward pan rotation speed is controlled by channel 3 step step step step Note for programming If you want to keep the same direction of the pan movent around 0 DMX 25...

Page 11: ...rams which can be different for every fixture To set the program to be played see the Stand alone setting menu St AL Stand alone operation can be applied to the single fixture the fixture may be set to the master slave mode or controller mode or to multiple fixtures operating synchronously Synchronous operation of multiple fixtures requires that they must be connected on a data link and one of the...

Page 12: ...SEt DM In PAn 0 255 F PAn 0 255 SPEd 0 255 Func 0 255 VErS IC1 b IC2 b IC3 b PErS r PAn On Off dISP turn On Off d On On Off d Int 20 100 FEEd On Off MI SE 1 10 20 FAn S Auto HIGH PA Mo SP Mo ti Mo In Po PAn 0 255 Func 0 255 Stor dF SE MAn M PrE C Pan Pan 1 Pan3 SPEd SPd 1 SPd 5 Func Fun 1 Fun 3 MAn C Pan 0 255 F PAn 0 255 SPEd 0 255 Func 0 255 ...

Page 13: ...13 tESt St AL Audi On Off Auto Off tESt PrG 1 PrG 2 PrG 3 PLAY tESt PrG 1 PrG 2 PrG 3 Edit PrG 1 PrG 2 PrG 3 St 01 St 99 Pan 0 255 S tim 0 1 25 5 s COPY rESE SPEC CodE uPd M No Yes ...

Page 14: ...bL deactivates master slave setting 8 2 Slave control This function allows you to control the slaves from the master s control panel in a master slave operation Select this function from the main menu and press ENTER Browse the list of all connected slaves SL C 1 SL C 9 by pressing UP or DOWN Select the desired slave and press ENTER button The matching slave control panel is available from the mas...

Page 15: ...function allows you to change the display settings turn Select this function to turn the display by 180 d On This function allows you to keep the display on or to turn off automatically 2 minutes after last pressing any button on the control panel d Int Select this function to adjust the display intensity 20 min 100 max bL Co Blackout during movement correction Select this function to enable the b...

Page 16: ... values 8 5 Manual mode Select this menu to call up presetted positions of channel effects or direct control channel effects PrE C Presetted effect control Select this menu to call up presetted positions of the channel effects Man C Manual effect control Select this menu to control effects by control buttoms on the control board PAn a coarse pan movement F PAn a fine pan movement SPEd a pan speed ...

Page 17: ...nd press ENTER 2 Press UP or DOWN to select the desired fixture MASt SLA 9 and press ENTER button 3 Press UP or DOWN to select the desired program step St 01 St 99 and press ENTER button 4 Press UP or DOWN to select the desired item and press ENTER button Now you can edit by UP or DOWN buttons the DMX value 0 255 for selected item P End a total number of the program steps value 1 99 This value you...

Page 18: ...ect button If the conection is OK click Start Uploading button to start uploading It will take several minutes to perform software update If the option Incremental Update isn t checked all processors will be updated including processors with the same software version If you wish to update only later versions of processors enable the Incremental Update check box Avoid interrupting the process Updat...

Page 19: ...ror The message informs you that the fixture was addressed as a master and DMX signal is connected to its input Disconnect the DMX controller from fixture s input and address the fixture as the master again 11 Technical specifications Power supply EU model Voltage 208 230 240V AC 50 60Hz Fuse T 630 mA 230V US model Voltage 100 120 208 230 240 V AC 50 60Hz Fuse T 1 25 A 120V Power consumption 25 VA...

Page 20: ...onnect from the mains before starting any maintenance work More complicated maintenance and service operations are only to be carried out by authorized distributors Replacing the fuse Only replace the fuse by a fuse of same type and rating Before replacing the fuse unplug mains lead Procedure 1 Unscrew the fuseholder on the rear panel of the base with a fitting screwdriver from the housing anti cl...

Page 21: ...21 ...