28
FAn
The message informs you that the fixture was overheating and switched off. This message will appear on the
display if the fan speed operating "LOOF" was selected.
MbEr
This messsage informs you that the main PCB does not communicate correctly with the Control Board.
CIEr (color-wheel 1 error)
This messsage will appear after the reset of the fixture if the magnetic-indexing circuit malfunctions (sensor
failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB).The color-wheel
is not located in the default position after the reset.
C2Er (color-wheel 2 error)
This messsage will appear after the reset of the fixture if the magnetic-indexing circuit malfunctions (sensor
failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB).The color-wheel
is not located in the default position after the reset.
rGEr (rotating gobo-wheel error)
The message will appear after the reset of the fixture if the magnetic-indexing circuit malfunctions (sensor
failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The rotating
gobo-wheel is not located in the default position after the reset.
iGEr (rotating gobo indexing error)
The message will appear after the reset of the fixture and if the magnetic-indexing circuit malfunctions
(sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The
rotating gobo is not located in the default position after the reset.
SGEr
(static gobo-wheel error)
This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunctions (sensor
failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The static
gobo-wheel is not located in the default position after the reset.
PrEr (prism error)
This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunctions (sensor
failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The prism-
wheel is not located in the default position after the reset.
FtEr
This error message informs you that the fixture was overheating (occured if the ambient temperature is 45°
C or more) and that the relay switched off the lamp. This message will appear on the display until the temperature
will be on a suitable level, then the display will show the massage
"HEAt" meaning the lamp is too hot (explanation
see above).
SnEr
This message appears if the lamp lighting sensor is failed.
PoEr
This message will appear if the fixture was shortly disconnect from the main.
PAEr (Pan-yoke movement error)
This message will appear after the reset of the fixture if the yoke’s magnetic-indexing circuits malfunction
(sensors failed or magnet missing) or the stepping motor is defective. (Or its driving IC on the main PCB). The
yoke is not located in the default position after the reset.
tiEr (TILT-head movement error)
This message will appear after the reset of the fixture if the head’s magnetic-indexing circuit malfunctions
(sensor failed or magnet missing) or the stepping motor is defective. (Or its driving IC on the main PCB).The head
is not located in the default position after the reset.
MA.Er.(Master error)
The message informs you that the fixture was addressed as a master and DMX signal is connected to its
input.Disconnect the DMX controller from fixture's input and address the fixture as the master again.
courtesy of
www.sxsevents.co.uk
Phone: 0870 080 2342
email: [email protected]
Event production and Audio-Visual Services
www.sxsevents.co.uk