3. Installation
Fixtures must be installed by a Qualified electrician in accordance with all
national and local electrical and construction codes and regulations.
3.1 Connection to the mains
For protection from electric shock, the fixture must be earthed!
The Robin Spikie is equipped with auto-switching power supply that automatically adjusts to any 50-60Hz AC
power source from 100-240 Volts.
If you install a cord cap on the power cable to allow connection to power outlets, install a grounding-type (earthed)
plug, following the plug manufacturer’s instructions.
If you have any doubts about proper installation, consult a qualified electrician.
Core (EU)
Core (US)
Connection Plug Terminal Marking
Brown
Black
Live
L
Light blue
White
Neutral
N
Yellow/Green Green
Earth
This device falls under class one and must be earthed (grounded)!
Design of the Robin Spikie allows to connect several fixtures to AC mains power in one interconnected daisy
chain using power input and throughput connectors. Needed daisy chain cords are stated in the chapter
“Technical specifications “
The max. number of connected fixtures depends on the AC mains power voltage and fixture version:
EU version (CE)
US version (cETLus)
29 fixtures at power supply= 230V
17 fixtures at power supply= 230V
26 fixtures at power supply= 208V
15 fixtures at power supply= 208V
15 fixtures at power supply= 120V
9 fixtures at power supply= 120V
Actual numbers of fixtures may differ from values stated above as you have to take into account the length of
supply cables, circuit breaker etc. at projecting of the fixtures installation Do not overload the supply line and
the connecting leads.
Wiring and connection work must be carried out by qualified staff!
Summary of Contents for ROBIN SPIKIE
Page 1: ... Version 1 0 Version 1 1 ...
Page 12: ...12 ...
Page 27: ...27 11 Photometric diagrams ...
Page 28: ...28 ...
Page 29: ...29 ...
Page 30: ...30 ...