8. Error and information messages
Tilt Err
This message will appear after the reset of the fixture if the head´s magnetic-indexing circuit malfunctions (sen
-
sor failed or magnet is missing) or the stepping motor is defective or its driving IC on the PCB. The head is not
located in the default position after the reset.
Pan Err
This message will appear after the reset of the fixture if the head´s magnetic-indexing circuit malfunctions (sen
-
sor failed or magnet is missing) or the stepping motor is defective or its driving IC on the PCB. The head is not
located in the default position after the reset.
Zoom Err
The messages will appear after the reset of the zoom module if the zoom lens is not located in the default
position.
Prism Err
The messages will appear after the reset of the if the prism is not in the default position.
Rod Err
The messages will appear after the reset of the flower effect if the rod is not in the default position.
Short Err
The message informs you that short circuit has occured on the LED PCB.
Clean Air Fil
This icon signalizes that cleaning period of the air filter has elapsed and you have to clear air filter in the fixture
base and reset the menu item "R Ti".