Eminere Inground 

 

We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable 

gland before inserting it into the body of the gland and an adequate layer of the paste LOCTITE 577 on the 

thread of the gland body.  

Remove end caps from cable glands before passing cables into the junction box.  

Fully tighten cable gland nuts and check that cables are properly fastened in the cable glands.  

Note: every cable gland has to be covered with the end cap if this cable gland is not used for cable passing.  

3.

 

After checking  all connections, fill the junction box with synthetic resin. Make sure that the End cap is 

inserted in unused cable gland and the earth wire for cover is pulled out of the junction box before filling it. 

At filling of the junction box proceed according instructions stated on the bag of the resin. 

The junction box (20) has to be fully poured in the resin.  

 

Prepared junction box  and resin bag.  

 

 

 

 

Junction box filled with resin. 

 

 

 

Earth wire 

Summary of Contents for ANOLIS Eminere Inground 2

Page 1: ...Version 1 1 ...

Page 2: ...le of contents 1 Safety instructions 3 2 Fixture exterior view 4 3 Installation 4 3 1 Mounting the Eminere Inground 5 4 Technical specifications 12 5 Cleaning and maintenance 15 5 1 Disposing of the product 15 6 ChangeLog 15 ...

Page 3: ...alls under protection class I Therefore this fixture has to be connected to a mains socket outlet with a protective earthing connection Do not connect this fixture to a dimmer pack LED light emission Risk of eye injury Do not look into the beam from a short distance without suitable protective eyewear Do not look at LEDs with magnifiers or similar optical instruments that may concentrate the light...

Page 4: ...d modifications on the fixture are forbidden due to safety reasons Operate the fixture only after having familiarized yourself with its functions Do not permit operation by persons not qualified to operate the fixture If this device will be operated in any way different to the one described in this manual the product may suffer damages and the warranty becomes void Furthermore any other operation ...

Page 5: ...m the mounting sleeve 1 by unscrewing the six cap head allen bolts 5 3 In sleeve that Emineres inground wil be installed side by side the four holes 10 on the side of the mounting sleeve serve for attaching next mounting sleeve by means of the four screws M5x10 2 with washer and nuts Two rubber grommets 3 insert to the holes 9 on the side of the mounting sleeve which you will use for passing cable...

Page 6: ...Eminere Inground is equipped with auto switching power supply that automatically adjusts to any 50 60Hz AC power source from 120 277 Volts The Emineres Inground should be connected to the E box E box Daisy E box Star E box Pro E box Lite which allows power supply of the Emineres Inground and their control Do not connect disconnect Emineres Inground to the E box and each other when they are under v...

Page 7: ...ection Brown L Purple Data Blue N Orange Data Yellow Green earth Shielding Data ground 0V Wiring of the Eminere cable US version Core Power Connection Core DATA Connection Black L Red Data White N Orange Data Green earth Shielding Data ground 0V The three cable glands M20 21 are intended for cable of diameter of 6 12mm Cable gland M20 ...

Page 8: ...roperly fastened in the cable glands Note every cable gland has to be covered with the end cap if this cable gland is not used for cable passing 3 After checking all connections fill the junction box with synthetic resin Make sure that the End cap is inserted in unused cable gland and the earth wire for cover is pulled out of the junction box before filling it At filling of the junction box procee...

Page 9: ...over plates end 15 middle 23 and continuous 22 Insert the cover plate middle 23 between two mounting sleeves and screw cover plates to the Emineres Inground by means of the countersunk allen head bolts M5x25 16 Cover plates overview Single fixture End fixture in a row of fixtures Middle fixture in a row of fixtures 1 Cover plate end optional 2 Cover plate continuous optional 3 Cover plate middle o...

Page 10: ...ng Important the item E box mode has to be set at Pass Thr Personality E box mode Pass Thr in the E box menu DMX addressing of connected Emineres Inground has to be done manually by means of the Robe Universal Interface or its wireless version Robe Universal Interface WTX and a software RDM Manager See the E box user manual The tables below state max theoretical number of Emineres connected to the...

Page 11: ...m 15 32 32 32 50 m 9 22 32 32 70 m 6 16 23 32 100 m 4 11 16 23 Cable length is a total cable length between E box and last connected Eminere Example of connection E box Daisy Total cable length L1 L2 L3 Max total cable length between one LED output of the E box and last connected Eminere Inground must not exceed 100m ...

Page 12: ...35 x 70 70 x 35 15 x 90 90 x 15 Wallwasher Wide Wallwasher Projected lumen maintenance 60 000 hrs L70 25 C 77 F Interface Protocol USITT DMX512 RDM Compatible drivers E box Daisy 1 output 1 Main power Input Control DMX Art Net sACN W DMX control RDM Pixel control 1px 1ft 120 277V Input Connection via terminal blocks inlets via grommet IP67 E box Star 6 outputs 1 Main power Input Control DMX Art Ne...

Page 13: ...luminium Welded instalation sleeve for pre instalation Tempered glass Cooling system Convection Total heat dissipation Eminere Inground 2 154 BTU h calculated Eminere inground 4 290 BTU h calculated Protection factor CE IP 67 US Suitable for wet location Impact rating CE IK9 Operating ambient temperature range 20 C 40 C 4 F 104 F Operating temperature 80 C Ambient 40 C 176 F Ambient 104 F Connecti...

Page 14: ...Eminere Inground 14 Dimensions All dimensions in mm inch Eminere Inground 2 Eminere Inground 4 Dimensions with mounting sleeve All dimensions in mm inch Eminere Inground 2 Eminere Inground 4 ...

Page 15: ...maintenance or cleaning work Rinse off loose dirt with low pressure water spray Wash the housing with a soft brush or sponge and a mild non abrasive washing detergent Rinse it Maintenance and service operations are only to be carried out by a qualified person Should you need any spare parts please use ROBE OEM parts 5 1 Disposing of the product To preserve the environment please dispose or recycle...

Reviews: