and at 300 - 600 charging cycles, they have to reckon with a drop in performance of only 

approx. 20%. 

With a non-optimal charger, the capacity is significantly reduced with every charge/discharge

and  thus  also  the  service  life.  Storage  at  too  high  or  too  low  temperatures  may  cause  a

gradual reduction in capacity.

General warnings - Avoid dangers! 

Do not burn batteries. Never immerse the cells in liquids. Keep batteries / cells out of the reach of 

children.  Never  disassemble  LiPo  batteries.  Disassembling  a  battery  may  cause  internal  short 

circuits. Gas generation, fire and explosion or other problems can be the result. The electrolytes 

and electrolyte vapours contained in the LiPo batteries are harmful to health. Avoid in any case 

direct contact with electrolytes. If electrolytes come into contact with skin, eyes or other parts of the 

body, rinse immediately with plenty of fresh water and seek medical advice. 

Remove all batteries not required in the model. Always charge batteries in time. Store batteries on 

a  non-flammable,  heat-resistant  and  non-conductive  base!  Fully  discharged  Li-Po  batteries  are 

defective and must not be used again! If the battery is out of service, disconnect it from all loads 

such as speed controllers, as they always consume a little power even if they are switched off. 

Otherwise the battery could be destroyed by deep discharge. 

Special instructions for charging LiPo batteries 

Since  we  cannot  monitor  the  correct  charging  and  discharging  of  the  cells,  any  warranty  is 

excluded due to faulty charging or discharging. Only approved chargers with balancer may be 

used for charging Li-Po batteries. The maximum charging capacity must be limited to 1.05-times 

the battery capacity. Example: 700 mAh battery = 735 mAh max. charging capacity. Make sure 

that the number of cells and the discharge end voltage are set correctly. Observe the operating 

instructions  of  your  charger/discharger.  The  battery  to  be  charged  must  be  placed  on  a  non-

flammable,  heat-resistant  and  non-conductive  base  during  the  charging  process!  When 

charging, keep all combustible or highly flammable objects away. Batteries may only be charged 

and discharged under supervision. In principle, LiPo batteries connected in series may only be 

charged together in the pack if the voltage of the individual cells does not differ by more than 0.1 

V from each other. If the deviation in the voltage of the individual cells is greater than 0.1 V, the 

cell voltage must be adjusted as precisely as possible by individual cell charging or discharge. 

Under  these  conditions,  LiPo  batteries  with  max.  1  C  charging  current  may  be  charged.  The 

indication 1 C charge current in mA corresponds to the capacity in mAh; i. e. 200 mA for a 200 

mAh battery. Avoid a voltage of more than 4.2 V per cell in any case, as this will permanently 

damage  the  cell  and  may  cause  fire.  In  order  to  avoid  overcharging  of  individual  cells  in  the 

pack,  the  cut-off  voltage  should  be  set  to  values  between  3.1  V  -  3.15  V  per  cell  for  a  longer 

service life. You can also charge batteries with a lower voltage for safety and longer service life. 

After each charging process, check that one of the cells in the pack has a voltage of more than 

4.2V.  All  cells  must  have  the  same  voltage.  If  the  voltage  of  the  individual  cells  deviates  from 

each other by more than 0.1 V, the cell voltage must be equalized by individual cell loading or 

single cell discharge. In order to avoid overloading the cells after prolonged use in packs, they 

should be charged individually on a regular basis. Never charge the battery cells with incorrect 

polarity. If the batteries are charged with reversed polarity, there are abnormal chemical reactions 

and the battery becomes unusable.  This can cause fractures, smoke and flames. 

ROCONTROL programming card

Instruction manual

Summary of Contents for ROCONTROL

Page 1: ...ume no liability Careful well considered handling during operation protects against personal injury and damage to property Carry out maintenance and inspection of your models and electrical equipment...

Page 2: ...table for persons under 14 years of age Commissioning may only be carried out under the constant supervision of an adult who is familiar with the hazards Before every operation check the seat of the m...

Page 3: ...and the discharge end voltage are set correctly Observe the operating instructions of your charger discharger The battery to be charged must be placed on a non flammable heat resistant and non conduc...

Page 4: ...sing can easily be damaged by sharp objects such as needles knives nails motor connections soldering or similar Damage to the foil will render the battery unusable The battery must therefore be instal...

Page 5: ...ke is engaged the engine stops immediately when the accelerator is switched off lever is moved to the lowest position 3 Undervoltage protection If soft cut off is selected the controller gradually red...

Page 6: ...connect it to the program card at the upper right corner the connection is marked with BEC 3 For a HV controller with a separate short three wire programming cable please disconnect the receiver cabl...

Page 7: ...of connected LiPo cells LED glows ROCONTROL programming card music function deactivated automatic detection automatic detection automatic detection automatic detection automatic detection automatic de...

Page 8: ...ves as proof of the commencement and expiry of this warranty Any repairs will not extend the warranty period The statutory warranty conditions apply For example you may only use the product properly b...

Reviews: