At the EXIT menu point you can jump to the “AUTO /
MANUAL” select option with the ENTER button; under
SOUND press the ENTER button to activate or disable the
buzzer.
To initiate the charge or discharge process confirm the
START menu point with the ENTER button.
You can now press the MODE button to select CHARGE,
DISCHARGE or DISC-CHAR.
Start the charge or discharge process by pressing the START
button.
The screen displays capacity, time, voltage and current. The
charger’s status (C=CHARGE, D=DISCHARGE, F=FINIS-
HED) is displayed at top left of the screen.
-
The charge or discharge process is ended by the automatic termination circuit or by the
operator pressing the STOP button.
-
When you next connect the charger to its power supply, the unit automatically reverts to
the spot memory you last used.
Auxiliary functions
Adjusting the current during charging or discharging (manual mode only)
Use the + / - buttons to change the current during charging or discharging.
Additional information
Access via double button function (press + and - buttons simultaneously); leaf through with
the + or - buttons.
Input and output voltage
Peak and momentary voltage
Discharge voltage at start or end of the discharge process.
Operating instructions
POWER PEAK ULTIMATE
Order No.
8427
13
C 298mAh 0 : 05 : 29
31 . 55V 3 . 80A
EXIT
<-
SOUND
OFF
START
<-
MEMORY SELECT
0
CHARGE
START
0 ] NICD 21 CL
1800
Spot memory
CHARGE CURRENT
↔
4 . 5A
DISCHARGE CUR.
↔
2 . 5A
↔
IN/OUT VOLTAGE
11 . 950 Vi 31 . 550 Vo
↔
CHARGE VOLTAGE
30 . 075 Vp 30 . 075Va
↔
DISCH. VOLTAGE
27.300Vs 16.800Vc