background image

Method 2: Factory reset the remote control will force the remote control to be excluded from a network. (please 
refer to the part “Factory Reset” of this manual)

Note: Factory reset is not recommended for exclusion, please use this procedure only if the primary 
controller/gateway is missing or otherwise inoperable.

How to check whether the remote control already included to a network

Short press any button, if LED indicator blinks 3 times, the remote control does not belong to any network, if 
LED indicator turns on, it means the remote control has already been included to a network.

If the remote control already belongs to a network, follow the exclusion process before including it in your 
network. Otherwise inclusion of this device will fail.

Factory Reset 

Press and hold down both buttons    and       of Group 2 together for over 10 seconds, LED indicator turns on 
and then blinks 4 times quickly to indicate successful factory reset.

Association

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device 
is called association. In order to control a different device, the controlling device needs to maintain a list of 
devices that will receive controlling commands. These lists are called association groups and they are always 
related to certain events (e.g. button pressed). In case the event happens all devices stored in the respective 
association group will receive a common wireless command.

Association Groups: 

Each group supports maximum 5 nodes for association, the same device can be associated with multiple 
groups on the remote control simultaneously, to ensure better control experience, the remote control shall 
remove the associated devices that are not under working status from association groups in time.

Set and unset associations:

 (Note: All association information will be cleared automatically once the remote control is excluded from a 
network.)

There are two methods to set associations:
1. Set association by operating primary controller/gateway to send association command to the remote control:

When set association from primary controller/gateway, the remote control shall be activated first, if it is not 
activated, you should activate it manually.

The primary controller/gateway sends association command to the remote control using “Command Class 
ASSOCIATION” or “Command Class Multi Channel Association”

2. Set association by operating the remote control and devices to be controlled:

To control a Z-Wave device from the remote control the node ID of this device needs to be assigned to one of 
the two association groups. This is a three-step process: 
1. Press and hold down both buttons     and      of Group 2 over 3 seconds, LED indicator turns on.

2. Short press ON button of any group within 7s to associate the device to this group, short press OFF button of 
any group within 7s to remove association of the device from this group.

3. Operate the device to be controlled to send Node Information Frame (please refer to the device manual) 
within 10 seconds, or set the device to exclusion mode within 10 seconds, since it will send Node Information 
Frame in exclusion mode, LED indications are as follows:

LED blinks twice to indicate that the remote control failed to add the associated device (the association group 
has already added maximum quantity associated devices that it supports ).

LED blinks 5 times to indicate that the remote control added the associated device successfully.
LED blinks 8 times to indicate that the remote control removed the associated device successfully.

To remove all associated devices in an association group on the remote control directly:
1. Press and hold down both buttons    and      of Group 2 over 3 seconds, LED indicator turns on.

2. Click OFF button of any group on the remote control 5 times continuously within 7 seconds to remove all 
associated devices of this group, LED indicator blinks 8 times to indicate that the associated devices are 
removed successfully.

Association

Groups

Group

Name

Max

Nodes

Description

Group 1

Lifeline

5

1. Send Command Class "Device Reset Locally Notification V1" to 
associated devices of this group to report factory reset information 
when factory reset the remote control.
2. When remote control battery power value changes, send 
Command Class "Battery Report V1" to associated devices of this 
group to report power value information.
3. Short press or press and hold down any button to send scene 
activation command to the associated devices of this group using 
Command Class “Central Scene Notification V3”

Group 2

Launch 1

5

Short press      /       button of Group 2 to send ON/OFF command to 
associated devices of this group using Command Class "Basic Set 
V2".

Press and hold down      /      button of Group 2 to send light intensity 
increase/decrease command to associated devices of this group 
using Command Class "Multilevel V4".

Group 3

Launch 2

5

Short press      /       button of Group 3 to send ON/OFF 
command to associated devices of this group using 
Command Class "Basic Set V2".

Press and hold down      /       button of Group 3 to send 
light intensity increase/decrease command to 
associated devices of this group using Command Class 
"Multilevel V4".

Operating the device

Group 2:
Click to turn on, Press and
hold down to increase light
intensity

Group 2:
Click to turn off, Press and
hold down to decrease light
intensity

Group 3

Group 3

Press and hold down both keys together for 3s to be added to or
removed from Z-Wave network by Z-Wave master (primary) controller.

Reviews: