INSTALLATION 

 Remove all the packaging materials and tape, as well as any protective plastic 

from  the  machine.    Clean  off  any  glue  residue  left  over  from  the  protective 
plastic using methylated spirit. 

 Place the Grill Station on a firm, level surface in the required position. Before 

connecting  the  grill  to  the  power  supply  ensure  that  all  the  controls  are  in  the 
“OFF”  position.    Turn  all  controls  on  and  off  to  familiarise  yourself  with  their 
operation. 

 National  Standards  exist  outlining  the  positioning,  spacing  and  ventilation 

requirements  when  installing  new  appliances.    These  Standards  should  be 
consulted  and  new  equipment  should  be  installed  accordingly.    In  any 
situation where specifications allow a distance of less than 100 mm we would 
still 

recommend

  that  a  well-ventilated  air  gap  of  not  less  than  100  mm  be 

maintained.    If  the  machine  is  near  particularly  heat-sensitive  materials 
common sense should be employed in determining sufficient distancing. 

 Do not place the Grill Station above other equipment that may give off heat. 

AUSTRALIAN MODELS 

For  the  GSA610  and  GSA810  models  plug  the  machine  into  a  single  phase, 
10 Amp  power  point.  For  the  GSA815  models,  plug  the  grill  into  a  single  phase 
15 A power point. The GSA815 models will not plug into a 10 A power point.   

EXPORT MODELS (-G, -F AND -M MODELS) 

Export models can plug into a standard 13 Amp United Kingdom (Type G), 16 Amp 
European (Type E or F) or South African (Type M) power point.  

 

For all units a 

minimum

 clearance of 25mm is required at the back of the unit to allow 

the  arms  to  pivot  freely  preventing  damage  to  any  adjacent  wall  or  equipment.  Any 
damage caused  to adjacent surfaces or  equipment as  a result  of the unit being too 
close  to  a  wall  will  not  be  covered  by  warranty.  Roband

®

  recommends  a  minimum 

gap of 100 mm be maintained all around the unit to allow adequate ventilation and to 
prevent any damage to heat sensitive materials. 

We recommend the use of an RCD (Residual Current Device) rated at not less than 
30 mA for circuit protection when using these units.  Note that if one RCD is used to 
protect multiple socket outlets, the RCD shall be appropriately rated so as to allow up 
to 30 mA from these machines alone.

 

 

 

Summary of Contents for GSA610

Page 1: ...plate models S R ST and RT Special Features Timer Alarm Advanced Control Safety Systems Embedded Elements for Rapid Heating Fast Recovery and Maximum Life High Quality Rapid Heating Aluminium Non sti...

Page 2: ...rates Nisa Trading LLC Ph 649 274 1354 9714 396 6132 Roband Australia is a wholly Australian owned company and has been manufacturing quality commercial catering equipment for the food service industr...

Page 3: ...STALLATION 3 OPERATION 4 COOKING GUIDELINES 6 GENERAL SAFETY 7 CLEANING CARE MAINTENANCE 8 SPECIAL NOTES REGARDING NON STICK COATED EQUIPMENT 10 TROUBLESHOOTING 11 SPECIFICATIONS 12 CIRCUIT DIAGRAM 13...

Page 4: ...customers or staff is minimised with additional signage if necessary Due to the obvious heat hazard Roband recommends that these units be kept out of reach of children In the case of new personnel tra...

Page 5: ...said unit within 24 hours of receipt No claims will be accepted or entertained after this period RCM Roband products have been designed and manufactured to comply with any and all specifications set o...

Page 6: ...above other equipment that may give off heat AUSTRALIAN MODELS For the GSA610 and GSA810 models plug the machine into a single phase 10 Amp power point For the GSA815 models plug the grill into a sing...

Page 7: ...the bottom plate only and turns on the left amber indicator light Off To turn the unit off return the switch to the Off position Note the Top Bottom and Top amber indicator lights glow only when the...

Page 8: ...efore using for the first time each day Place the food on the bottom plate and close the top plate onto the food A timer is provided with all GS Series Grill Stations This timer should be used as a gu...

Page 9: ...1min 30sec Rest for 3 minutes 20mm Steak Medium 240 C 2 mins Rest for 3 minutes 20mm Steak Medium Well 240 C 2mins 30 sec Rest for 3 minutes Meat Patties 240 C 1 min 10sec Chicken Breast 240 C 3 mins...

Page 10: ...ing as this may expose sharp edges Do not remove any cover panels that may be on the machine This unit can get very hot ensure everyone is aware that the machine is operating and take care to avoid co...

Page 11: ...perature NON STICK COATED T SERIES Plates should be cleaned at the end of each day using a soft cloth dampened with only hot soapy water with the machine turned OFF but while the plates are still warm...

Page 12: ...cals can result in damage to parts of the machine Many cleaning chemicals are unsuited to polycarbonates or plastics and may also damage stainless steel and aluminium Although every care is taken duri...

Page 13: ...and performance of the non stick coating on your equipment Do NOT use at high temperatures over 240 C Do NOT use metal spatulas scrapers tongs or knives when transferring food in or out of the plates...

Page 14: ...indicating the machine has power The Thermostat knob is not loose or broken rendering the thermostat inoperable Check Appendix A at the back of this manual RCD S If the top plate is toasting faster th...

Page 15: ...er Frequency 50 60Hz 50 60Hz 50 60Hz Power Consumption 2150 2250 Watts 2200 2400 Watts 2860 3120 Watts Amps 9 6 10 0 13 0 Width mm 435 560 560 Height mm 220 220 220 Depth mm 490 490 490 Weight kg 17 3...

Page 16: ...l Models Note This circuit diagram has been provided for reference and to assist qualified service and repair agents only Under no circumstances should persons not suitably qualified attempt repairs t...

Page 17: ...Roller Bearing and Bracket Assembly 2 MS0519 5 Minute Mechanical Timer Aluminium Knob 1 PC0146 Washer 1 4 x 1 2 x 1 16 klingerite 1 PC0418 Bush Machined Sintered PTFE 2 PS0129 Foot Foot Cap Set inclu...

Page 18: ...TS FOR GSA815R Part No Description Qty Part No Description Qty HC0191 GSA810R Top Element Plate Assy Aluminium Ribbed 890W 230V 1 HC0199 GSA815R Top Element Plate Assy Aluminium Ribbed 1170W 230V 1 HC...

Page 19: ...ve been taken into consideration when an RCD circuit was installed To avoid unwanted tripping due to leakage currents and transient disturbances care should be taken to ensure that the sum of the leak...

Page 20: ...Page 17 NOTES Record any preferred times or settings etc here to act as a quick reference for other users...

Page 21: ...Page 18 NOTES Record any preferred times or settings etc here to act as a quick reference for other users...

Page 22: ...Page 19 NOTES Record any preferred times or settings etc here to act as a quick reference for other users...

Page 23: ...ve goods or materials pursuant to this warranty must be authorized by Roband Australia prior to any action being taken The company reserves the right to reject a claim for warranty if it is not comple...

Page 24: ...ER LEADING PRODUCTS AVAILABLE Sycloid Toaster DRINK MIXERS HIGH PERFORMANCE DEEP FRYERS VITAMIX BLENDERS GRILLMAX TOASTERS NOAW Slicers Manufactured Imported in Australia by Authorised Distributor Age...

Reviews: