INSTALLATION
Remove all the packaging materials and tape, as well as any protective plastic
from the machine. Clean off any glue residue left over from the protective
plastic using methylated spirit.
Place the Grill Station on a firm, level surface in the required position. Before
connecting the grill to the power supply ensure that all the controls are in the
“OFF” position. Turn all controls on and off to familiarise yourself with their
operation.
National Standards exist outlining the positioning, spacing and ventilation
requirements when installing new appliances. These Standards should be
consulted and new equipment should be installed accordingly. In any
situation where specifications allow a distance of less than 100 mm we would
still
recommend
that a well-ventilated air gap of not less than 100 mm be
maintained. If the machine is near particularly heat-sensitive materials
common sense should be employed in determining sufficient distancing.
Do not place the Grill Station above other equipment that may give off heat.
AUSTRALIAN MODELS
For the GSA610 and GSA810 models plug the machine into a single phase,
10 Amp power point. For the GSA815 models, plug the grill into a single phase
15 A power point. The GSA815 models will not plug into a 10 A power point.
EXPORT MODELS (-G, -F AND -M MODELS)
Export models can plug into a standard 13 Amp United Kingdom (Type G), 16 Amp
European (Type E or F) or South African (Type M) power point.
For all units a
minimum
clearance of 25mm is required at the back of the unit to allow
the arms to pivot freely preventing damage to any adjacent wall or equipment. Any
damage caused to adjacent surfaces or equipment as a result of the unit being too
close to a wall will not be covered by warranty. Roband
®
recommends a minimum
gap of 100 mm be maintained all around the unit to allow adequate ventilation and to
prevent any damage to heat sensitive materials.
We recommend the use of an RCD (Residual Current Device) rated at not less than
30 mA for circuit protection when using these units. Note that if one RCD is used to
protect multiple socket outlets, the RCD shall be appropriately rated so as to allow up
to 30 mA from these machines alone.