6.
Settings
After checking the correct operation of the controller in conjunction with the vibratory feed system it is
advisable to restrict the user to feeder throughput settings only.
Setting the feeder throughput:
Press the P key twice and adjust the throughput with the cursor keys (Code C. 000).
Parameter:
Code
Factory
setting:
Entry Code:
Vibratory feeder
•
Amplitude (throughput)
0...100 %
A.
0 %
000, 002
The following variable parameters are available for setting up the feed system
Parameter:
Display
Factory
setting:
Entry Code:
Vibratory feeder
•
Amplitude (throughput)
0...100 %
A.
0 %
000, 002, 020
096
•
Maximum control limit (U
max
)
5...100 %
P.
90 %
008, 020, 096
•
Vibrating frequency
35...140 Hz
(5...300 Hz)
F.
100 Hz
008, 020
040, 096
•
Soft start ramp up
0...60 Sek.
/.
0,1 Sec.
020, 096
•
Soft stop ramp down
0...60 Sek.
\.
0,1 Sek.
020, 096
•
Switch to external set point
0 / I
E.S.P.
0
003
•
Set point 0(4)...20 mA
0 / I
4.20
0
003
•
Potentiometer set point
0 / I
POT.
0
003
•
Coarse / Fine control
0 / I
S.P.2.
0
003
•
Invert enable
0 / I
-En.
0
003
•
Pulse feed
0 / I
HOP.
0
064
•
On time delay (only if HOP. = I)
0...60 Sec.
H.
1,0 Sec.
004, 064
•
Off time delay (only if HOP. = I)
0...60 Sec.
h.
1,0 Sec.
004, 064
•
Invert hopper sensor (not active)
0 / I
-Ho.
0
004, 064
Track control
•
Switch on time delay
0...60 Sec.
I.
1 Sec.
007, 167
•
Switch off time delay
0...60 Sec.
O.
1 Sec.
007, 167
•
Invert sensor
PNP / PNP
invers
-SE.
PNP
007, 167
•
Sensor Time-out
0 / I
E.En.
0
015, 167
•
Sense time delay (Sensor Time-out)
1...240 Sec.
E.
180 Sec.
015, 167
•
Switch off time air valve
0...60 Sec.
A.i.
4 Sec.
015
Service
•
Display actual output current
i.
040
•
Display actual frequency
F.
040
•
Save user settings
PUSH.
143
•
Recall factory settings
FAC.
210
•
Recall user settings
US.PA.
210
•
Hide programming menus
0 / I
Hd.C.
0
117
•
Hide set point adjustment
0 / I
di.S.
0
137
•
Display software version
001