RNA ESM 3000 Series Operating Instructions Manual Download Page 25

 

 

RNA Group 

Headquarters 
Manufacturing and Sales 

Rhein-Nadel Automation GmbH 
Reichsweg 19-23 
D-52068 Aachen 

Phone: +49 (0) 241-5109-0 
E-Mail: [email protected] 

www.RNA.de

 

 

 

Further RNA group companies: 

 

 
Manufacturing and Sales 
Focus: Pharmaceutical Industry 

PSA Zuführtechnik GmbH 
Dr.-Jakob-Berlinger-Weg 1 
D-74523 Schwäbisch Hall 
Phone: +49 (0) 791 9460098-0 
Fax: +49 (0) 791 9460098-29 
E-mail: [email protected] 

www.psa-zt.de

 

 
 

 

Manufacturing and Sales 

RNA Automation Ltd. 
Unit C 
Castle Bromwich Business Park 
Tameside Drive 
Birmingham B35 7AG 
United Kingdom 
Phone: +44 (0) 121 749-2566 
Fax: +44 (0) 121 749-6217 
E-mail: [email protected] 

www.rnaautomation.com

 

 
 

 

Manufacturing and Sales 

HSH Handling Systems AG 
Wangenstr. 96 
CH-3360 Herzogenbuchsee 
Switzerland 
Phone: +41 (0) 62 956 10-00 
Fax: +41 (0) 62 956 10-10 
E-mail: [email protected] 

www.handling-systems.ch

 

 
 

 

Manufacturing and Sales 

Pol. Ind. Famades c/Energia 23 
E-08940 Cornella de Llobregat (Barcelona) 
Spain 
Phone: +34 (0)93 377-7300 
Fax: +34 93 377-6752 
E-mail: [email protected] 

www.vibrant-RNA.com

 

www.vibrant.es

 

 

 

 

 

 

 

 

 
   

Further manufacturing sites 

   

of the RNA Group 
 
Manufacturing 
Lüdenscheid branch 

Rhein-Nadel Automation GmbH 
Nottebohmstraße 57 
D-58511 Lüdenscheid 
Phone: +49 (0) 2351 41744 
Fax: +49 (0) 2351 45582 
E-mail

[email protected]

 

 
 
 

Produktion 
Ergolding branch 

Rhein-Nadel Automation GmbH 
Ahornstraße 122 
D-84030 Ergolding 
Phone: +49 (0) 871 72812 
Fax: +49 (0) 871 77131 
E-mail: 

[email protected] 

 
 
 

Produktion 
Remchingen branch 

Rhein-Nadel Automation GmbH 
Im Hölderle 3 
D-75196 Remchingen-Wilferdingen 
Phone: +49 (0) 7232 - 7355 558 
E-mail: 

[email protected]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for ESM 3000 Series

Page 1: ...Operating Instructions Controller for vibratory drive systems ESR 3000 ESM 3000...

Page 2: ...s 11 8 2 2 Operating frequency of the feeder coil 11 8 2 3 Measurement of the output voltage and current 11 8 3 Putting the equipment into operation 11 9 Setting Instructions 12 9 1 User adjustment of...

Page 3: ...014 35 EU and Electromagnetic Compatibility Directive 2014 30 EU We hereby declare that the product meets the following requirements Low Voltage Directive 2014 35 EC Electromagnetic Compatibility Dire...

Page 4: ...tection of the described product and connected equipment Isolate from mains before installation or dismantling work as well as for fuse changes or post installation modifications Observe the prescribe...

Page 5: ...g frequency is also dynamically adjusted to compensate for resonant frequency changes caused by load changes In normal operating mode without accelerometer the feeder remains constant at the set frequ...

Page 6: ...ent of these sensitive parameters An interface option can be used to provide an RS232 or Fieldbus Profibus DP connection 2 1 Track control The output can be switched ON and OFF from a track component...

Page 7: ...ime Out message active if after adjusted time no material is recognized by the sensor adjustable with parameter E not on 16 A units 2 3 6 Air valve output 24 VDC Output for air blast comes on with fee...

Page 8: ...Operating temperature 0 45 C Storage temperature 10 80 C Altitude 1000 m 0 5 rated current reduction for each additional 100 m The units are provided with switch on current damping However it is stil...

Page 9: ...1 Sec 020 096 Soft stop ramp down 0 60 Sek 0 1 Sek 020 096 Switch to external set point 0 I E S P 0 003 Set point 0 4 20 mA 0 I 4 20 0 003 Potentiometer set point 0 I POT 0 003 Coarse Fine control 0 I...

Page 10: ...thorized adjustment the adjustment parameters in the user menus are protected A code must be entered to open the user menus There are different pass codes for each function group Setting adjustments a...

Page 11: ...ncy adjustment and so this should be checked with a true RMS instrument for each new application as well as monitoring the coil for heat build up The coil should be designed for the correct operating...

Page 12: ...quency otherwise on hitting the resonant frequency it is possible to achieve a high amplitude with a low output voltage An analog effective value current indicating unit moving iron meter must be conn...

Page 13: ...m limit 1 Adjust set point to zero 2 Set parameter P maximum limit to 50 3 Adjust set point to 100 4 Increase the limit P from 50 until the required amplitude is reached 5 The full set point range of...

Page 14: ...e out not active I Sensor time out active E Sensor time out sec P P P P P P P P P P F Running mode P 0 Sensor time out not active I Sensor time out active E Sensor time out sec P P P Code C 015 P Runn...

Page 15: ...ting unit moving iron meter must be connected into the output circuit Resonant frequency is reached when there is a maximum amplitude for a minimum output current To achieve a stable feed system there...

Page 16: ...EN_2020 07 05 2020 SJ I Hide menus Running mode P P P P 9 2 9 Recall user or factory settings Code C 210 9 2 10 Hide parameter menus Code C 117 Return to factory settings Return to user settings Runni...

Page 17: ...y during setting up Sensor fault only when regulation mode is selected Accelerometer not working or faulty ERROR Reset through Menu C009 Sensor time out After sensor time out has elapsed ERROR Reset i...

Page 18: ...e input socket X5 Status output socket X1 Output Feeder X0 Main supply 110 240 V 50 60 Hz 1 24 V 3 GND 4 Input 1 2 3 4 1 2 3 PE 1 24 V 2 Input 3 GND 1 2 3 4 1 24 V 3 GND 4 Input 1 2 3 4 1 L 2 N 3 nc 4...

Page 19: ...Accelerometer 5 6 7 1 2 3 4 8 9 E 24V E S A 10k 0 10V 0 4 20mA 7 8 7 8 R 500 OHM extern 10V 12 24V DC 4 5 21 22 23 55 54 53 52 51 27 26 29 28 25 24 INPUT GND 24 V SW 31 32 33 34 35 36 37 L N A2 A1 PE...

Page 20: ...for 6 A panel mounting versions Recommended method of terminating screen of output cable The output cable to the feeder must be screened to conform with EMC regulations When a potentiometer is connect...

Page 21: ...Rhein Nadel Automation GmbH 21 VT BA ESR ESM3000 EN_2020 07 05 2020 SJ 13 Dimensions Enclosed construction Enclosed construction 6A Enclosed construction 12A...

Page 22: ...Rhein Nadel Automation GmbH 22 VT BA ESR ESM3000 EN_2020 07 05 2020 SJ 13 1 Dimensions Panel mounting...

Page 23: ...voltage limit allows 110v coils to be used on a 230V supply without damage Parameter Display Factory setting Entry code Enable service menu 0 I En C 0 127 Adjust current limit 0 100 I 100 040 Set low...

Page 24: ...in parallel the coil current is the sum of all individual currents Enable Service Mode The actual service menu is accesed by opening the service mode The normal service menu containing the output cur...

Page 25: ...6 CH 3360 Herzogenbuchsee Switzerland Phone 41 0 62 956 10 00 Fax 41 0 62 956 10 10 E mail info handling systems ch www handling systems ch Manufacturing and Sales Pol Ind Famades c Energia 23 E 08940...

Reviews: