General Specifications 

Transmission method

Frequency modulated light via two optical fibers

Multimode:

 850nm

Single-mode: 

1310nm

Maximum Fiber Loss / 

Distance*

Multimode:

8dB / 1.2 miles (2km

Single-mode:    

8dB / 9 miles (15km)

SM Long Haul:  

26dB / 31 miles (50km); minimum 8dB 

*Note: Distances equated using industry standard fiber and connector attenuation.
(Multimode: 3.5dB/km, Single-mode: 0.4db/km, + 0.5dB per connector, + 0.3dB per splice)

Fiber Type

Multimode: 62.5/125

μ

m, 50/125

μ

m ; Single-mode: 9/125

μ

m

Fiber Connector Types

ST or SC 

Analog Bandwidth

300 Hz to 3.4 KHz

Maximum Analog Data Rate

9600 bps (9.6Kbps)

DDS Data Rate

2.4Kbps and 4.8Kbps

Contact Closure Input

Dry Contact Closure of 2000 Ohms maximum

Contact Closure Output

Normally Open, Solid State Relay, 150mA 220VAC 330VDC

Response Time

On: 1.4

μ

s  /  Off: 1.9 msec (Dry Contact Only)

LED Indicators

Yellow Contact Output Status (LD1)

ON: Closed, OFF: Open

Red Contact Input Status (LD2)

ON: Closed, OFF: Open

Channel Noise

< 20dBrnC (15dBrnC typical)

DC Resistance Limits

2000 Ohms typical for 50V DC CO battery

Nominal Impedance

600 Ohm input and output

Insertion Loss

0dB +/- 0.5dB each direction

Overload Level

8dBm into 600 Ohms

Surge Protection

PTC thermistors, zener diodes and varistors

Power Requirements

Line: 15mA ; Local: 24-56VDC, card current limits at 18mA

Power Connector

Screw type connector terminal, 12-26 AWG

Powering Method

Simplexed line power or local DC power supply connected to AUX. P.S.

Simplex Current 

Output Option

18mA@24VDC on XMIT pairs, Sub side only

Operating Temperature

-40° to +158° F (-40° to +70° C), 95% non-condensing

Dimensions

7 ”x 4” x 1” Standard RLH Fiber Link Card form factor

Warranty

Limited Lifetime

 

Visit 

www.fiberopticlink.com

 for warranty details

 

RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com

 

Page 

"

6

Summary of Contents for 8806-1238-02-SM11

Page 1: ...l hardened Fiber Link Card system may be installed into any RLH card housings and is covered by our Limited Lifetime Warranty Powering The 4 Wire Data with Contact Closure CO and Sub cards may be powe...

Page 2: ...city When transporting the card carry it in an ESD safe container such as the antistatic bag provided with the card Before handling cards discharge yourself of static electricity by physical bodily co...

Page 3: ...t model mode and fiber connector type Have a clean dry installation environment ready Required for installation RLH card housing for RLH Fiber Link Cards 24 56VDC 18mA local power sources as needed Th...

Page 4: ...The red LED is ON when the input is active and OFF when no input is present The yellow LED is ON when the contact closure output is closed and OFF when the output is open 2 RX TX E M OUTPUT E M INPUT...

Page 5: ...put is not polarity sensitive The CO card can operate off of simplexed line power on the SEND INPUT and RECEIVE OUTPUT pairs where available Troubleshooting If trouble is encountered verify all connec...

Page 6: ...1 9 msec Dry Contact Only LED Indicators Yellow Contact Output Status LD1 ON Closed OFF Open Red Contact Input Status LD2 ON Closed OFF Open Channel Noise 20dBrnC 15dBrnC typical DC Resistance Limits...

Page 7: ...istance Fiber Description Part Number Multimode ST 2km 1 25 mi 62 5 m CO Card 8806 1238 02 SM11 Sub Card 8806 1248 02 SM11 Multimode SC 2km 1 25 mi 62 5 m CO Card 8805 1238 02 SM11 Sub Card 8805 1248...

Page 8: ...2 1672 Toll Free 1 800 877 1672 Toll Free 1 866 DO FIBER Fax 714 532 1885 Email info fiberopticlink com Web site www fiberopticlink com RLH Industries Inc 936 N Main Street Orange CA 92867 USA T 714 5...