background image

Guidelines for handling terminated fiber cable 

"

  

Do not bend fiber cable sharply. Use gradual and smooth bends to avoid damaging glass fiber.

Keep dust caps on fiber optic connectors at all times when disconnected.

Do not remove dust caps from unused fiber.

Keep fiber ends and fiber connectors clean and free from dust, dirt and debris. Contamination will cause 
signal loss.

Do not touch fiber ends.

Store excess fiber on housing spools or fiber spools at site

Installation 

 

4-Wire Data with Contact Closure System Diagram 

Before installing 

Check  for  shipping  damage.  In  case  of  damage,  file  a  claim  immediately  with  the  carrier,  then  contact  RLH 

customer service. 

Check the contents to ensure correct model, mode and fiber connector type. 

Have a clean, dry installation environment ready. 

Required for installation 

RLH card housing for RLH Fiber Link Cards. 

24-56VDC@18mA local power sources as needed. 

The 4 Wire Data with Contact Closure Fiber Link Card is designed to be installed into any RLH card 
housing. The housing should be properly installed before installing the card. All electrical and fiber optic 
connection are made directly onto the card. 

RX

TX

E & M

OUTPUT

E & M
INPUT

RECEIVE
OUTPUT

RECEIVE

INPUT

24-56V

AUX. P.S.

RX

TX

E & M

OUTPUT

E & M
INPUT

RECEIVE
OUTPUT

RECEIVE

INPUT

24-56V

AUX. P.S.

FIBER

 UP TO

50km / 31 mi.

DATA

(2W OR 4W)

 MAY BE LINE/SPAN

POWERED

Central 

Office/ 

PBX

Customer

Supplied

Equipment

24-56VDC

Power 

 DRY CONTACT

INPUT

DRY CONTACT

OUTPUT

DRY CONTACT 

INPUT

DRY CONTACT

OUTPUT

CO

CARD

SUB

CARD

 

RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com

 

Page 

"

3

Summary of Contents for 8806-1238-02-SM11

Page 1: ...l hardened Fiber Link Card system may be installed into any RLH card housings and is covered by our Limited Lifetime Warranty Powering The 4 Wire Data with Contact Closure CO and Sub cards may be powe...

Page 2: ...city When transporting the card carry it in an ESD safe container such as the antistatic bag provided with the card Before handling cards discharge yourself of static electricity by physical bodily co...

Page 3: ...t model mode and fiber connector type Have a clean dry installation environment ready Required for installation RLH card housing for RLH Fiber Link Cards 24 56VDC 18mA local power sources as needed Th...

Page 4: ...The red LED is ON when the input is active and OFF when no input is present The yellow LED is ON when the contact closure output is closed and OFF when the output is open 2 RX TX E M OUTPUT E M INPUT...

Page 5: ...put is not polarity sensitive The CO card can operate off of simplexed line power on the SEND INPUT and RECEIVE OUTPUT pairs where available Troubleshooting If trouble is encountered verify all connec...

Page 6: ...1 9 msec Dry Contact Only LED Indicators Yellow Contact Output Status LD1 ON Closed OFF Open Red Contact Input Status LD2 ON Closed OFF Open Channel Noise 20dBrnC 15dBrnC typical DC Resistance Limits...

Page 7: ...istance Fiber Description Part Number Multimode ST 2km 1 25 mi 62 5 m CO Card 8806 1238 02 SM11 Sub Card 8806 1248 02 SM11 Multimode SC 2km 1 25 mi 62 5 m CO Card 8805 1238 02 SM11 Sub Card 8805 1248...

Page 8: ...2 1672 Toll Free 1 800 877 1672 Toll Free 1 866 DO FIBER Fax 714 532 1885 Email info fiberopticlink com Web site www fiberopticlink com RLH Industries Inc 936 N Main Street Orange CA 92867 USA T 714 5...

Reviews: