65-2451RK Hydrogen Transmitter • 1
Overview
This manual describes the 65-2451RK hydrogen transmitter. This manual also describes
how to install, start up, configure, maintain, and calibrate the transmitter when it is used
with a gas monitoring controller. A parts list at the end of this manual lists replacement
parts and accessories for the hydrogen transmitter.
Specifications
Table 1 lists specifications for the hydrogen transmitter.
WARNING: When using the 65-2451RK, you must follow the instructions and warnings
in this manual to assure proper and safe operation of the 65-2451RK and to
minimize the risk of personal injury. Be sure to maintain and periodically
calibrate the 65-2451RK as described in this manual.
Table 1:Specifications
Description
Specification
Target Gas
Hydrogen
Area Classification
Explosionproof for Class I, Groups B, C, and D
Sampling Method
Diffusion
Signal Output
4 to 20 mA
Detection Range
0 to 100% LEL
Response Time
90% in 45 seconds
Accuracy
± 5% of reading or ± 2% LEL (whichever is greater)