RKC INSTRUMENT V-TIO-P Instruction Manual Download Page 3

 

IMS01P08-E3

 

3

(4) Control output (CH1),  (5) Control output (CH2) 

M: Relay contact output 
V:  Voltage pulse output 0/12 V DC 
4:  0 to 5 V DC 

 

5:  0 to 10 V DC 

 

6:  1 to 5 V DC 
7:  0 to 20 mA DC 

 

8:  4 to 20 mA DC 

(6) Event input (DI)    [Optional] 

N: None 
1: Control RUN/STOP 
2:  Event interlock release

 

(7) (8)  Event output 1 (DO1)    [Optional]

 

*

 

(9) (10) Event output 2 (DO2)    [Optional]

 

*

 

[(7), (9) code: Channel selection] 
N: None 

 

1:  Input channel 1   
2:  Input channel 2 
[(8), (10) code: Output type] 
N: None 

 

A: Deviation high 

 

B: Deviation low 
C: Deviation high/low  

 

D: Band 
E: Deviation high with hold action   
F: Deviation low with hold action 
G: Deviation high/low with hold action 
H: Process high 

 

 

J: Process low 
K: Process high with hold action 

 

L:  Process low with hold action 
Q: Deviation high with re-hold action 

 

R: Deviation low with re-hold action 
T: Deviation high/low with re-hold action 
P: Heater break alarm 

 

 

1:  Control loop break alarm 
2: Burnout 

 

 

3:  Temperature rise completion 

(11) CT type 

(Each channel common code)

 

P: CTL-6-P-N 

 

S: CTL-12-S56-10L-N 

(12) Communication protocol   

1: Modbus/TCP 

*

 When “N” is selected in (7) or (9), (8) or (10) becomes “N.” 

 

• 

For heat/cool PID control (V-TIO-Q), input channel 
2 becomes unused. 

• 

For heat/cool PID control (V-TIO-Q), Control output 
(CH1) corresponds to the heating output and 
Control output (CH2) corresponds to the cooling 
output. 

• 

Heater break alarm function cannot be used when 
control output is voltage/current output. 

 
 
 
 
 
 
 

 

If any of the products are missing, damaged, or if your 
manual is incomplete, please contact RKC sales office 
or the agent.

 

 

3. PARTS DESCRIPTION 

 

Terminal cover

Indication lamps 1

Address setting

switch 

Terminal cover

Indication lamps 2

Event 

connector 

*

 

Ethernet communication side Temperature control side 

FAIL/RUN 
RX/TX 
EVENT1 
EVENT2 
EVENT3 
EVENT4 

5

4

3

2

1

0

9 8 7

6

5

5

4

3

2

1

0

9 8 7

6

5

Modular connector 

for Ethernet

RJ-45

Indication lamp 3 

Indication lamp 4 

 

 

 

 

FAIL/RUN 
RX/TX 
EVENT1 
EVENT2 
EVENT3 
EVENT4 

 

 
 
 
[Indication lamps 1] 

 

FAIL/RUN (for temperature control) 

When normally: 

Green lamp:  ON (RUN) 

When abnormally: 

Red lamp: 

ON (FAIL) 

During self-diagnostic error: 

Green lamp:  flashing   

 

RX/TX (for internal communication) 

During data send and receive:  Green lamp:  ON 

 

EVENT 1 to 4 

Display various states by setting. 

Display contents: Event 1 state, Event 2 state, Comprehensive event state,   

Output state, Control state 

[Indication lamps 2] 

 

FAIL (for Ethernet communication) 

When normally: 

Red lamp: 

OFF 

When abnormally: 

Red lamp: 

ON 

 

RUN (for Ethernet communication) 

When normally: 

Green lamp:  ON 

When abnormally [Module configuration error, input error]: 
 

Green lamp:  slow flashing 

Data collection just after the power is turned on: 
 

Green lamp:  rapid flashing 

 

TX 

During data send: 

Green lamp:  flashing 

 

RX 

During data receive: 

Green lamp:  flashing 

[Indication lamps 3] 

 

Link 

10BASE-T link: 

Amber lamp:  ON 

100BASE-TX link: 

Green lamp:  ON 

[Indication lamps 4] 

 

Activity 

Half-duplex; activity: 

Amber lamp:  Momentary ON 

Full-duplex; activity: 

Green lamp:  Momentary ON 

 
 

 

Accessories

 

End Plate ................................................................... 2 
Joint connector cover................................................. 2 
Instruction Manual (IMS01P08-E3) ........................... 1 

Installed when provided with the event input or output (optional).

 

 

Indication
lamp 2 

Indication
lamp 1 

Temperature control side

Ethernet communication side

FAIL 

RUN 

T

X

R

X

Summary of Contents for V-TIO-P

Page 1: ...nals must be enclosed in the instrumentation panel to avoid electric shock by operating personnel All precautions described in this manual should be taken to avoid damage to the instrument or equipment All wiring must be in accordance with local codes and regulations All wiring must be completed before power is turned on to prevent electric shock instrument failure or incorrect action The power mu...

Page 2: ...dule for Ethernet heat control Q Module for Ethernet heat cool control 2 Control action Each channel common code For heat control F PID action with autotuning AT reverse action D PID action with autotuning AT direct action For heat cool control B Heat cool PID action with autotuning AT air cooling W Heat cool PID action with autotuning AT water cooling 3 Input range Each channel common code Thermo...

Page 3: ...office or the agent 3 PARTS DESCRIPTION Terminal cover Indication lamps 1 Address setting switch Terminal cover Indication lamps 2 Event connector Ethernet communication side Temperature control side FAIL RUN RX TX EVENT1 EVENT2 EVENT3 EVENT4 5 4 3 2 1 0 9 8 7 6 5 5 4 3 2 1 0 9 8 7 6 5 Modular connector for Ethernet RJ 45 Indication lamp 3 Indication lamp 4 FAIL RUN RX TX EVENT1 EVENT2 EVENT3 EVEN...

Page 4: ...e this one The communication speed sets the same value as a temperature control side DIP switch 3 setting Temperature control side setting Set the communication speed and data bit configuration for internal communication by using the DIP switch 3 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON DIP switch 3 Right side ON OFF Terminal base Module mainframe 1 2 Communication speed OFF OFF Don t set this one ON...

Page 5: ...with the event connector but the same also when not provided with the connector Depth in connector mounting Conduct installation in consideration of the sizes of the connector and cable when connector connected 110 Usage example of SRVP 01 Unit mm Approx 50 Connector plug SRVP 01 sold separately 5 3 DIN rail Mounting Mounting procedures 1 Pull down the mounting bracket at the bottom of the module ...

Page 6: ... RTD input use low resistance lead wire with no difference in resistance between the three lead wires To avoid noise induction keep input signal wire away from instrument power line load lines and power lines of other electric equipment If there is electrical noise in the vicinity of the instrument that could affect operation use a noise filter Shorten the distance between the twisted power supply...

Page 7: ...ptional This is a connector installed in the V TIO P V TIO Q module only when provided with the event input DI or the event output DO 1 6 Event connector socket Circuit configuration 24 V DC 1 2 3 DI 4 5 6 Load DO1 DO2 Load Attention in Connector plug Wiring Use the following connector plug as that connected to the event input output connector Connector plug is sold separately SRVP 01 Front screw ...

Page 8: ...action is selectable Specify when ordering Heat cool control is selectable Specify when ordering Additional function Autotuning function Events Number of events 2 points channel Event type Temperature event Deviation high Deviation low Deviation high low Band Process high Process low Heater break alarm Control loop break alarm Burnout Temperature rise completion Option Event input DI Number of inp...

Reviews: