Parameter table                                                                                                                                                     

#1:Factory set value

Symbol

Name

Setting range

Description

#1

 Current

 transformer

  input 1 (CT1)

  0.0 to 100.0 A

 [Only display]

  Display input value from the current

 transformer.

  [Displayed only when the instrument has

 

  the heater break alarm ]

 First alarm

 (ALM1)

 Second alarm

 (ALM2)

 

For temperature input:

  Deviation alarm, Process alarm,

 

SV alarm:

  -1999 to +9999 

°

C[

°

F ] or

  -199.9 to +999.9 

°

C[

°

F ]

  For voltage/current inputs:

  Deviation alarm :

    -span to +span (Within 9999)
  Process alarm, SV alarm:
    Same as input range

  Set the first alarm set value and

  second alarm set value.

  Alarm differential gap:

  Temperature input: 2 or 2.0 

°

C[

°

F]

 Voltage/current inputs:
                                  0.2 % of span

Temperature

input: 50(50.0)

Voltage/

current inputs:

 5.0

 Heater break

  alarm 1 (HBA)

  0.0 to 100.0 A

                                            See *1.

  Alarm value is set by referring

  to input value from the current

 transformer (CT).

  Used only for single-phase.

            0.0

 Control loop

 break alarm

 (LBA)

  0.1 to 200.0 min.

  (0.0 can not be set.)

                                            See *2.

  Set control loop break alarm

 set value.

            8.0

 LBA deadband

 (LBD)

 Temperature input:

  0 to 9999 

°

C[

°

F ]

 Voltage/current inputs:

    0 to 100 % of span

  Set the area of not outputting LBA.

  No LBA deadband functions with "0"

 set.

Differential gap :

Temperature input  0.8 

°

C[

°

F ]

Voltage/current inputs    0.8 % of span

              0

  Autotuning (AT)   0: AT end or AT suspension

  1: AT start

 Turns the autotuning ON/OFF.

       0

  Self-tuning (ST)   0: ST suspension

  1: ST start

 Turns the self-tuning ON/OFF.

       0

 Proportional

 band  (P)

 Temperature input:

1(0.1) to span or

9999(999.9) 

°

C[

°

F ]

 Voltage/current inputs:

1 to 100.0 % of span

  Set when PI,PD or PID control is

 performed.

  For heat/cool PID action: Proportional

  band setting on the heat-side.

*ON/OFF action control when set

 to "0(0.0)."

  Differential gap :

 Temperature input  2 or 2.0

°

C[

°

F]

  Voltage/current inputs 0.2 % of span

Temperature

input: 30(30.0)

Voltage/

current inputs:

 3.0

 Integral time

  ( I )

  1 to 3600 sec

  *PD control when set to 0 sec.

  Set the time of integral action which

  eliminates the offset occurring in

 proportional control.

            240

 Derivative time

 (D)

  1 to 3600 sec

  *PI control when set to 0 sec.

  Set the time of derivative action

  which prevents ripples by predicting

  output changes and thus improves

 control stability.

              60

 Anti-reset

 windup (ARW)

  1 to 100 % of heat-side

 proportional band.

  *"0" setting: integral action OFF

  Overshooting and undershooting

  are restricted by the integral effect.

            100

 Heat-side

 proportioning

 cycle  (T)

  1 to 100 sec (0 can not be set.)

  *Not displayed if the control

output is current output.

  Set control output cycle.

  For heat/cool PID action:

Heat-side proportioning cycle

        See *3.

 Cool-side

 proportional

 band  (Pc)

  1 to 1000 % of heat-side

 proportional band.

  (0 can not be set.)

  Set cool-side proportional

  band when heat/cool PID action.

            100

 Deadband (db)

 Temperature input:

  -10 to +10 

°

C[

°

F ] or

  -10.0 to +10.0 

°

C[

°

F ]

 Voltage/current inputs:

    -10.0 to +10.0 % of span

  Set control action deadband

  between heat-side and cool-side

 proportional bands.

  Minus (-) setting results in overlap.

        0 or 0.0

(Continued on the next page. )

Summary of Contents for CB400 Series

Page 1: ...lowing damage which the user or third party may suffer Damage incurred as a result of using this product Damage caused by product failure which cannot be predicted by RKC Other indirect damage In orde...

Page 2: ...mm 48 Panel cutout 25 45 0 8 0 0 6 0 92 30 96 110 8 91 8 44 8 1 Rubber packing option This instrument corresponds to a panel thickness of 1 to 10 mm CB400 1 CB700 Unit mm Panel cutout 86 8 67 8 67 8...

Page 3: ...A Resistive load Control output rated Relay contact output 250 V AC 3A Resistive load Voltage pulse output 0 12 V DC Load resistance 600 or more Current output 4 to 20 mA DC Load resistance 600 or les...

Page 4: ...LM2 R S CB500 PV SV SET C C C C 1 2 4 5 6 7 3 AT OUT1 OUT2 ALM1 ALM2 SET R S CB400 PV SV C C C C Measured value PV display unit Green Displays measured value PV Displays various parameter symbols depe...

Page 5: ...s the self tuning ON OFF 0 Proportional band P Temperature input 1 0 1 to span or 9999 999 9 C F Voltage current inputs 1 to 100 0 of span Set when PI PD or PID control is performed For heat cool PID...

Page 6: ...e the LBA setting time 3 Relay contact output 20 sec Voltage pulse output Trigger output for triac driving Triac output 2 sec 4 Relay contact output 20 sec Voltage pulse output Triac output 2 sec 5 De...

Page 7: ...h value to match the controlled object 6 4 Self tuning ST function The ST function is used to automatically calculate and set adaptive PID constants anytime when the power is turned on the SV is chang...

Page 8: ...06 to 0 0 50 0 07 to 0 0 100 0 08 to 0 0 200 0 09 to 0 0 300 0 10 to 0 0 500 0 P P P P P 0 to 5 V DC 1 to 5 V DC 0 to 20 mA DC 4 to 20 mA DC 01 01 01 01 4 6 7 8 to 0 0 100 0 Pt100 JPt100 1 0 to 399 0...

Reviews: