Inspector D4000
™ Laser
Operator
’s Guide
RJS, Minneapolis, MN
002-7858
12
Two choices are available in Auto Print Mode:
1. On: (For the TP140A / TP140 / TP40 / Computer) Both ISO/ANSI and Traditional analysis will
print automatically after a symbol is scanned.
2. Off: You must press the print button to print.
(See Appendix H - Print Functions)
The next selection is Output Device:
Output Device
TP140
Three output choices are available:
1. When TP140 is enabled, the data is output in the format required by a TP140/TP140A print-
er
2. When TP40 is enabled, data output is in the format of analysis only
3. When Computer is enabled, data is output in computer readable format (text and graphics)
(See Section 9.0, Connect to Computer)
The next selection is Scans/Analysis:
Scans/Analysis
Single
From this screen you may choose the number of scans (from 1 (single) to 10 or continuous) to be
used in the analysis. When set to continuous the D4000 will scan and grade bar codes until the
Laser trigger is released, then the Continuous Results screen will be displayed:
(See 8.5 Continuous Mode)
The last selection is Comparison Mode:
Comparison Mode
Off
When Comparison Mode is On, the first bar code scanned after turning Comparison Mode On will
be saved as the Master bar code. All bar codes scanned will be compared to the Master bar code
and if the encoded data does not match then a No Match error will be displayed.
(See 7.2, Comparison Mode)
Note:
When all Setup selections have been made, the RJS In-
spector D4000 will navigate back to the Main Menu au-
tomatically.
All setup parameters are retained in non-volatile memory
and will be saved until changed by you
—
even if the power
is turned off.