Inspector 5000
™ Auto Optic
Operator
’s Guide
RJS, Minneapolis, MN
003-4500
46
Line 17
Displays the ISO/ANSI Right Quiet Zone Pass/Fail result
and the size of the quiet zone (the minimum quiet zone
size varies by Symbology and Symbology Specification):
Quiet Zone (right)
Pass 10X
Line 18
Displays the calculated Narrow Bar Width (NBW or X-dim)
by pressing the Select button:
Narrow Bar Width
Press SEL
With the Narrow Bar Width screen displayed, use a ruler
to measure the distance from the left most bar to the right
most bar and enter this value into the Barcode Width field.
The Inspector 5000 will automatically determine and
display the Narrow Bar Width (or Magnification, depending
the Symbology). Press the Select button to return to the
Grading screen.
Line 19
Displays the Ratio Pass/Fail result and the numeric ratio
of the Wide to Narrow bar widths (the acceptable ratio
values vary by Symbology and Symbology Specification,
see Table B-2):
Ratio
Pass 2.3
Note: The Ratio field will not be displayed if the ratio is not
applicable (UPC, EAN, or Code 128)
Line 20
Displays the Inter Character Gap result and the space
between encoded characters and is expressed as a
multiple of the X dimension
Inter Character Gap
1.02X
Note: The Inter Character Gap field will only be displayed if
applicable (Code 39 and Codabar)