15

 

IA4

 - 

Instant Access 4 Mode 

 

(Instant Access Mode range: 

LAT

,

 PULS

Grp

, Default value: 

LAt

This controls the behavior of Instant Access button 4. 

LAT

(latching) is the default behavior: each press of the IA button 

toggles it between on and off. 

PuLs

 (momentary pulse) means that the switch stays on while you’re holding the button 

down, but turns off as soon as you release the button (this is particularly useful for tap tempo control). 

Grp

 (group) 

means that pressing this switch will turn off all other IA switches that are set to 

Grp 

– the MasterMind will insure that 

no more than one switch in the group can be on at a time. 

 
IA5

 - 

Instant Access 5 Mode 

 

(Instant Access Mode range: 

LAT

,

 PULS

Grp

, Default value: 

LAt

This controls the behavior of Instant Access button 5. 

LAT

(latching) is the default behavior: each press of the IA button 

toggles it between on and off. 

PuLs

 (momentary pulse) means that the switch stays on while you’re holding the button 

down, but turns off as soon as you release the button (this is particularly useful for tap tempo control). 

Grp

 (group) 

means that pressing this switch will turn off all other IA switches that are set to 

Grp 

– the MasterMind will insure that 

no more than one switch in the group can be on at a time. 

 
SNDA

 -  Send Always 

 

(Send Always range: 

On

,

 OFF

, Default value: 

On

When this parameter is on, pressing a preset button (1 through 5) will always cause the MasterMind to send the 
corresponding PC and CC messages, even if the MasterMind is already on the selected preset. If this parameter is off, 
the MasterMind will only send PC and CC messages when selecting a new preset – pressing the same preset button 
repeatedly will not generate multiple sets of PC and CC messages. 
 

PCAL

 -  Pedal Calibration 

 

(Yes/No selection: Press Bank Up (Yes) to start pedal calibration, Bank Down (No) to exit Setup Mode) 

Pressing Bank Up when this parameter is selected will cause the MasterMind to begin expression pedal calibration. 
Calibration insures that the MasterMind knows the upper and lower limits of pedal travel, which are needed to provide 
the best pedal performance. When in pedal calibration, the display will read 

CAL

. With the expression pedal plugged in 

to the MasterMind, move the pedal to the fully up position, then to the fully down position. On the MasterMind display, 
an indicator on the right side of the screen should move to the top when the pedal is fully depressed, and should move 
to the bottom when the pedal is raised up. 
 
Once you’ve moved the pedal through its full range of motion, press any button on the MasterMind to exit calibration. 
 

SEND

 -  MIDI Dump Send 

 

(Yes/No selection: Press Bank Up (Yes) to send, Bank Down (No) to exit Setup Mode) 

Pressing Bank Up when this parameter is selected will cause the MasterMind to send its configuration data out the MIDI 
Out port. If the MIDI Out port is connected to the MIDI In port of another MasterMind, the data will be transferred to the 
MasterMind. The data can also be sent to a PC that has a MIDI interface and SysEx librarian software for backup 
purposes. 
 

InIt

 -  Initialize 

 

(Yes/No selection: Press Bank Up (Yes) to initialize, Bank Down (No) to exit Setup Mode) 

Pressing Bank Up when this parameter is selected will cause the MasterMind to erase its memory, returning to the 
factory default state. Be careful! This wipes the entire memory and there’s no way to restore your settings unless you 
have previously backed them up to a PC or another MasterMind. 
 

Preset Setup 

Once you’ve finished 

Global Setup

, you can set up each preset. In this mode, you set which Program Change number is 

sent to each Program Change destination, and set which controller value is sent for each Continuous Controller for 
every preset. You can also set up the Function button and Expression Pedal for each preset in this mode. 
 

Entering Preset Setup 

 
The MasterMind goes straight to Preset Setup when you enter 

Setup Mode

. If you happen to be in 

Global Setup

, you 

can press the 

1 / Function Select

 button to switch to Preset Setup. The red LED above the 

1 / Function Select 

button 

will light to tell you that Preset Setup is active. You are now ready to edit the first parameter. 

Summary of Contents for MasterMind

Page 1: ...MasterMind User s Manual RJM Music Technology Inc...

Page 2: ......

Page 3: ...s Manual Version 1 6 1 December 6 2010 Corresponds to Mastermind firmware version 1 4 RJM Music Technology Inc 2525 Pioneer Ave Suite 1 Vista CA 92081 1 760 597 9450 email support rjmmusic com web ww...

Page 4: ...Copyright 2009 2010 RJM Music Technology Inc All Rights Reserved RG 16 Amp Gizmo MasterMind and the RJM logo are trademarks of RJM Music Technology Inc...

Page 5: ...ts 5 Controlling Multiple RJM Music Products 6 Alternate Presets 6 Instant Access Mode 7 Expression Pedal 8 Pedal Calibration 8 Remote Access 9 Phantom Power 9 Remote Tuner Display 10 Setup Mode 11 En...

Page 6: ......

Page 7: ...and can also control devices by use of the Function button and Expression Pedal input MasterMind Features Plug and play operation with other RJM products Transmits up 4 Program Change messages and 8 C...

Page 8: ...2 Front Panel...

Page 9: ...3 Rear Panel...

Page 10: ...power supplies of 9 to 18 volts AC or DC The power supply must be able to deliver at least 200mA The connector is a standard 5 5mm 2 1mm barrel connector and can be either center negative or center p...

Page 11: ...ll cause the bank number to count up or down automatically When you re done selecting the bank the preset number in the display will flash indicating that you now need to select a preset number Press...

Page 12: ...sound A004 Drive sound w flanger 005 Solo sound A005 Solo sound w harmonizer With this setup you can press the 1 button to get your clean sound then press Function to turn chorus on or off as desired...

Page 13: ...ode the MasterMind buttons perform new functions Buttons 1 through 5 pressing one of these buttons will send a continuous controller message Each button press will toggle between on 127 and off 0 valu...

Page 14: ...dals on the market will work Pedals that have a stereo TRS 1 4 output jack and have the potentiometer wiper connected to the ring conductor of the output jack will definitely work The Rocktron Hex is...

Page 15: ...MIDI Out jack connected to the rest of your rig When the MasterMinds are turned on you ll notice that all but the first MasterMind will have the Remote indicator lit This means that the controllers ar...

Page 16: ...t this communication you will need to connect a second MIDI cable from the MIDI output of your effects processor to the Remote In jack of your Mastermind The tuner display automatically turns on when...

Page 17: ...l flash to tell you that you are now in Setup Mode and will remain flashing until you leave Setup Mode Setup Mode Buttons When in setup mode the buttons secondary functions are active These are the gr...

Page 18: ...uts you into Global Setup The green LED above the button will light to tell you that Global Setup is active You are now ready to edit the first parameter Watching the display you ll see that it altern...

Page 19: ...16 CH CC5 disabled Default value CH CC number range c000 c127 Default value c084 Sets the MIDI channel and CC number for the fifth Continuous Controller destination Press 2 Program CC Number to select...

Page 20: ...5 etc IA Instant Access Instant Access range On OFF Default value OFF Turning on this parameter will enable Instant Access mode With this parameter on the Function button will activate Instant Access...

Page 21: ...the MasterMind knows the upper and lower limits of pedal travel which are needed to provide the best pedal performance When in pedal calibration the display will read CAL With the expression pedal plu...

Page 22: ...t 001 defaults to 001 preset 002 defaults to 002 preset 003 defaults to 003 etc Sets the program number for the first Program Change destination Press 2 Program CC Number to select the program number...

Page 23: ...for the fifth Continuous Controller destination Press 4 CC Value to set the value or press 3 CC On Off to quickly toggle between the most commonly used values 000 and 127 CC6 Continuous Controller 6 C...

Page 24: ...e receiving unit then enter Global Setup select the Send parameter and press Bank Up Note that the receiving MasterMind must be in normal operating mode to receive data The receiving unit s display wi...

Page 25: ...hantom Power Accepted over pins 6 and 7 of the MIDI Out jack same specs as above Phantom power is passed over pins 6 and 7 of the Remote In jack current limited to 500mA Do not connect phantom power a...

Page 26: ...n GM2 System On Yes No Turn GM System Off Yes No DLS 1 Yes No File Reference Yes No Controller Destination Yes No Key based Instrument Ctrl Yes No Master Fine Coarse Tune Yes No Other Universal System...

Page 27: ...Y N 17 General Purpose Controller 2 MSB Y N 18 General Purpose Controller 3 MSB Y N 19 General Purpose Controller 4 MSB Y N 20 Y N 21 Y N 22 Y N 23 Y N 24 Y N 25 Y N 26 Y N 27 Y N 28 Y N 29 Y N 30 Y...

Page 28: ...CC1 default 81 General Purpose Controller 6 Y N CC2 default 82 General Purpose Controller 7 Y N CC3 default 83 General Purpose Controller 8 Y N CC4 default 84 Portamento Control Y N CC5 default 85 Y N...

Page 29: ......