background image

Product Manual | Lynx™ Shielded Analog Input Module IA1‑M‑V

RJG, Inc.

iii

INTRODUCTION

Read, understand, and comply with all following 
instructions. This guide must be kept available 
for reference at all times.

DISCLAIMER

Inasmuch as RJG, Inc. has no control over the 
use to which others may put this material, it 
does not guarantee that the same results as 
those described herein will be obtained. Nor 
does RJG, Inc. guarantee the effectiveness or 
safety of any possible or suggested design for 
articles of manufacture as illustrated herein by 
any photographs, technical drawings, and the 
like. Each user of the material or design or 
both should make his own tests to determine 
the suitability of the material or any material 
for the design as well as the suitability of the 
material, process, and/or design for his own 
particular use. Statements concerning possible 
or suggested uses of the material or designs 
described herein are not to be construed as 
constituting a license under any RJG, Inc. patent 
covering such use or as recommendations 
for use of such material or designs in the 
infringement of any patent.

PRIVACY

Designed and developed by RJG, Inc. Manual 
design, format and structure copyright 2018 
RJG, Inc. content documentation copyright 
2018 RJG, Inc. All rights reserved. Material 
contained herein may not be copied by hand, 
mechanical, or electronic means, either whole 
or in part, without the express written consent 
of RJG, Inc. Permission will normally be granted 
for use in conjunction with inter‑company use 
not in conflict with RJG’s best interests.

ALERTS

The following three alert types are used as 
needed to further clarify or highlight information 
presented in the manual:

Term 

A definition of a term or terms used in the 

text.

NOTE 

A note provides additional information 

about a discussion topic.

CAUTION 

A caution is used to make the 

operator aware of conditions that can cause 

damage to equipment and/or injury to personnel.

Summary of Contents for Lynx IA1-M-V

Page 1: ...PRODUCT MANUAL Training and Technology for Injection Molding Lynx Shielded Analog Input Module IA1 M V...

Page 2: ...PRINT DATE 02 25 2019 REVISION NO 0...

Page 3: ...S 1 PROCESS MONITORING AND CONTROL 1 OPERATION 1 INJECTION PRESSURE 1 SCREW POSITION VELOCITY 1 DEW POINT 1 OTHER SUPPORTED SENSOR TYPES 2 DIMENSIONS 3 CABLE LENGTH 3 INSTALLATION INSTALLATION OVERVIE...

Page 4: ...RT ON PRESS POWER UP 11 INCORRECT INJECTION PRESSURE SCALING 11 CUSTOMER SUPPORT 12 RELATED PRODUCTS COMPATIBLE PRODUCTS 13 SHIELDED ANALOG INPUT MODULE CABLE C IA1 M 3M 13 LYNX SHIELDED SEQUENCE MODU...

Page 5: ...ed uses of the material or designs described herein are not to be construed as constituting a license under any RJG Inc patent covering such use or as recommendations for use of such material or desig...

Page 6: ...Lynx Shielded Analog Input Module IA1 M V Product Manual iv RJG Inc...

Page 7: ...ne temperature melt pressure mold deflection mold temperature power consumption revolution rate and vacuum INJECTION PRESSURE The IA1 M V is often used to acquire an injection pressure signal from ele...

Page 8: ...also supports the additional following sensor types Ejector Pin indirect Hydraulic Pressure Mold Temperature Barrel Temperature Coolant Temperature Coolant Flow Rate Delta Pressure Revolution Rate OPE...

Page 9: ...Product Manual Lynx Shielded Analog Input Module IA1 M V RJG Inc 3 DIMENSIONS CABLE LENGTH CABLE LENGTH The C IA1 M 3M is 9 8 ft 3 m long...

Page 10: ...Lynx Shielded Analog Input Module IA1 M V Product Manual 4 RJG Inc...

Page 11: ...output card on one end or to some other 0 10 V measurement device and connected to the IA1 M V on the other using the four pin connector The shielded analog input module is connected to the ID7 M SEQ...

Page 12: ...ust be located away from any static sources such as feeder tubes and material hoppers WIRING The C IA1 M 3M cable has colored coded wires to simplify installation Refer to the table below for the corr...

Page 13: ...ould be displayed in the Value column Record the machine value for the measurement at this time as well For example if using the IA1 M V to acquire injection pressure from the machine record the machi...

Page 14: ...er 5 Enter the machine value recorded in step 4 into the Maximum field and select the appropriate units of measurement 6 Enter the maximum voltage recorded in step 4 into the Voltage at Maximum Pressu...

Page 15: ...and robustness of the shielded analog input module and so are offering a one year warranty RJG s products are guaranteed against defects in material and workmanship for one year from the original dat...

Page 16: ...Lynx Shielded Analog Input Module IA1 M V Product Manual 10 RJG Inc...

Page 17: ...s started before machine is powered on Solution Always power the eDART on after the machine is powered on Analog signals tend have a spike or a sudden lurch from zero to a specific position voltage Of...

Page 18: ...Analog Input Module IA1 M V Product Manual 12 RJG Inc CUSTOMER SUPPORT Contact RJG s Customer Support team by phone or email RJG Inc Customer Support P 800 472 0566 Toll Free P 1 231 933 8170 www rjgi...

Page 19: ...ART System the C IA1 M 3M provides a connection from molding machines output card and the RJG Inc C IA1 M 3M LYNX SHIELDED SEQUENCE MODULE ID7 M SEQ The Lynx shielded sequence module ID7 M SEQ 2 at ri...

Page 20: ...YNX SHIELDED DUAL RELAY OUTPUT MODULE OR2 M The Lynx shielded dual relay output module OR2 M 2 at right is a shielded DIN rail mounted module that interfaces the eDART and sorting equipment or injecti...

Page 21: ......

Page 22: ...E A PTE LTD Singapore Republic of Singapore P 65 6846 1518 sales swg rjginc com en rjginc com FRANCE RJG FRANCE Arnithod France P 33 384 442 992 sales fr rjginc com fr rjginc com CHINA RJG CHINA Chen...

Reviews: