Product Manual | Piezoelectric Load Washer Sensor 211M18
15
SENSOR INSTALLATION CHECK
Verify that the each sensor and ejector pin pocket is machined correctly.
PRE‑ASSEMBLY CHECKS
1. Indentation Test (with Ejector Pin)
With the ejector sleeve installed, push on the ejector sleeve; verify the clearance of 0.01”
(0,25 mm (or ≤ 1/5 part thickness)) exists between the bottom of the ejector sleeve head
and the ejector retainer plate surface
.
2. Flush Test (with Sensor)
With the sensor installed in the ejector plate, verify that the sensor head is flush with the
ejector retainer plate.
POST‑ASSEMBLY CHECK
1. Flush Test (Full Stack)
With the sensor and ejector sleeve installed, and the ejector plate in the injection position,
fixed towards clamp plate, the ejector sleeve should be flush with the ejector plate/cavity
surface.
B-Plate or Cavity Insert
Ejector Retainer Plate
B Plate or Cavity Insert
Ejector Retainer Plate
Ejector Plate
Ejector Plate
Clamp Plate
Clamp Plate
Ejector Sleeve
Sensor
Sensor
Ejector Sleeve