Piezoelectric Load Washer Sensor 211M18 | Product Manual
12
CABLE CHANNEL
Machine a cable channel width of 0.28”
(7 mm [
3
AT RIGHT
]) MIN and depth of
0.310” (7,87 mm) to accommodate the
sensor stem for 1.89” (48 mm [
1
at right])
from center of sensor head:
this is also the
minimum bend length.
CAUTION
a
Do not bend the sensor cable
closer than the minimum bend
length; failure to comply will result
in damage to equipment.
Machine a cable channel width and depth
from the end of the sensor stem pocket out
of the mold of 0.25” (6 mm [
2
at right]).
1
1.89” (48 mm)
2
0.25” (6 mm)
3
0.28” (7 mm) wide by 0.25” (6 mm) deep
1
2
3
ALTERNATE INSTALLATION SPECIFICATIONS (
continued
)
Summary of Contents for 211M18