ULB-362B Underwater Locator Beacon
11
User’s Manual
January 2018
WARNING:
Hazardous chemicals are used in the beacon battery. Dispose
of the battery in accordance with local regulations.
Use the battery replacement procedure provided with the lithium battery
replacement kit P/N B362-B30-01 or B362-A30-01.
Tooling Requirements for Battery Replacement
Item
Part Number
1/2” Box End
Wrench
Commercially Available
Torque Adapter
B362-09111
Beacon Disposal
If it is necessary to dispose of the beacon, perform the Battery Check
referenced in Section 3 of this User’s Manual first.
If the battery voltage is 6.0 volts or more, remove the battery and dispose of
the battery and beacon in accordance with local regulations.
If the battery voltage is less than 6.0 volts, DO NOT remove the battery
access end cap and dispose of the beacon in accordance with local
regulations.
WARNING:
Failure to observe these precautions could result in the release
of hazardous chemicals.
Beacon Storage
When long-term storage is required, the beacon should be stored in a cool,
dry environment in its original shipping container.
Beacon Part Number
Battery Kit Part Number
ULB-362/18, ULB-362/37, ULB-362/27, ULB-362/45, ULB-
362PL/27, ULB-362PL/37, ULB-362A/27, ULB-362A/37
B362-01
ULB-362B/27, ULB-362B/37, ULB-372B/45, ULB-
362PL/B37
B362-B30-01