background image

ULB-362B Underwater Locator Beacon   

 

 

 

 

 

 

        

8

 

 

 

User’s Manual 

January 2018

 

 

Installation Procedures for ULB-362/PL  

 

Carefully unpack the beacon and inspect it for shipping damage.  If any 
damage is evident, it should be reported to the freight carrier and to RJE 
International, Inc.   
 

 

To mount the beacon, perform the following steps: 

 

1.  Ensure the beacon is mounted in the vehicle so that it has a clear path to send 

the acoustic signal. Avoid mounting it behind other equipment.   

 

2.  Mount the beacon with the water switch down to prevent accidental activation.  

 

3.

 

Male E/O Pigtail Connector, provided with the unit, is wired to 

Vehicle’s 

electronics module through a penetrator.  

 

4.

 

A ‘normal

ly 

closed’ electrical relay is installed in electronics module of the 

Vehicle. This relay is wired 

to the vehicle’s power supply. (see below diagram)

 

 

 

 

 
 

Figure 3-4 Wiring Diagram of the ULB-362PL/B37 

Summary of Contents for ULB-362/18

Page 1: ...ator Beacon User s Manual January 2018 P N 362 17001 A RJE INTERNATIONAL INC 15375 Barranca Parkway Suite I 112 Irvine California 92618 U S A www rjeint com Tel 1 949 727 9399 Fax 1 949 727 0070 e mai...

Page 2: ...RJE International Inc Materials may not be reproduced or disseminated without the prior written consent of RJE International Inc Changes RJE International Inc reserves the right to make changes to mee...

Page 3: ...ion and Checkout 5 Installation Considerations 5 Installation Procedures for ULB 362B and ULB362 02 Mounting Bracket 6 Installation Procedures for ULB 362 PL 8 Pre Deployment Tests 9 Battery Check 9 4...

Page 4: ...1 2 Installed in Mounting Bracket 2 Figure 1 3 Dimensions 2 Figure 1 4 Locating the ULB 362B After Water Activation 3 Figure 3 1 Mounting Bracket Hole Pattern 6 Figure 3 2 Securing the Mounting Bracke...

Page 5: ...z and 45kHz The beacons transmit an acoustic signal once every second after activation The acoustic output for the 30 day battery will remain above 157 0dB for 30 days RJE International Inc also offer...

Page 6: ...uction The beacon is contained in a water tight aluminum case capable of withstanding high impact shock and deep water immersion As shown in Figure 1 2 one of the end caps has a built in water activat...

Page 7: ...h the housing in the form of a tuned acoustic signal based on the frequency of the beacon 27kHz 37 5kHz or 45kHz Locating the Beacon When the beacon is immersed in water it will begin to radiate an ac...

Page 8: ...s 6 years from date of manufacture Battery Storage Life in Beacon 6 years from date of manufacture 160 5 dB re 1 Pa 1 meter Acoustic Output 160 5 dB re 1 Pa 1 meter Water immersion Activation Water im...

Page 9: ...sturdy structure without weakening the structure itself The beacon should be mounted in an area guarded against heavy equipment tearing loose and striking the beacon and should be mounted in a way th...

Page 10: ...rform the following steps 1 Ensure the beacon is mounted in the vehicle so that it has a clear path to send the acoustic signal Avoid mounted it behind other equipment 2 Mount the beacon with the wate...

Page 11: ...ULB 362B Underwater Locator Beacon 7 User s Manual January 2018 Figure 3 2 Securing the Mounting Bracket Figure 3 3 Installing the Beacon into the Mounting Bracket...

Page 12: ...beacon is mounted in the vehicle so that it has a clear path to send the acoustic signal Avoid mounting it behind other equipment 2 Mount the beacon with the water switch down to prevent accidental a...

Page 13: ...beacon Battery Check A high impedance minimum input impedance of 10 Megohms digital voltmeter can be used to measure the battery voltage Use the following procedure to measure the battery voltage 1 Pl...

Page 14: ...ns should be exercised when handling or storing the beacon The beacon should not be exposed to temperatures in excess of 71 C 160 F as the battery life can be reduced by storage in a high temperature...

Page 15: ...User s Manual first If the battery voltage is 6 0 volts or more remove the battery and dispose of the battery and beacon in accordance with local regulations If the battery voltage is less than 6 0 v...

Page 16: ...International Inc for a Case Number and shipping instructions RJE International Inc Tel 1 949 727 9399 Fax 1 949 727 0070 e mail sales rjeint com You will need to provide the following information to...

Page 17: ...OR FOR LOST OR CORRUPTED DATA LOSS OF BUSINESS LOSS OF PROFITS LOSS OF USE OF THE PRODUCT OR ANY ASSOCIATED EQUIPMENT COST OF CAPITAL COST OF SUBSTITUTE OR REPLACEMENT PRODUCT FACILITIES OR SERVICES...