86 | CX xx70 Appliance Specifications
CX 5070 and CX 7070 specifications
Power requirements and consumption
This table summarizes the power specifications for the systems. The systems are rated at the following
power characteristics when operating at nominal AC input voltages (120 V and 230 V).
Environmental specifications
This table summarizes the environmental requirements for the systems.
System
CX 5070
CX 7070
Configuration
All (M/H)
All (L/M/H)
PSU type
2 x 770 W
2 x 770 W
AC input
120 V
230 V
120 V
230 V
Max. amps.
3.0
1.5
5.3
2.7
Max. watts
298
291
527
520
Typical watts
238
232
422
416
Max VA
301
293
533
524
Power factor
98.96
99.16
98.96
99.16
BTU (typical)
814
794
1439
1418
CX 5070
CX 7070
Operating acoustic
7.0 BA sound power (Typical)
55 dBa sound pressure
7.0 BA sound power (Typical)
55 dBa sound pressure
Temperature
(operating)
10° to 35°C
50° to 95 F
10° to 35°C
50° to 95 F
Temperature (storage)
-40° to 70°C
-40° to 158°F
-40° to 70°C
-40° to 158°F
Relative humidity
50% to 90%, noncondensing with a
maximum wet bulb of 28°C (at
temperatures from 25° to 35°C)
50% to 90%, noncondensing with a
maximum wet bulb of 28°C (at
temperatures from 25° to 35°C)
Summary of Contents for SteelHead 5080
Page 10: ...10 Welcome Contacting Riverbed...
Page 16: ...16 Riverbed Software Licenses Upgrades and Image Signing Software upgrades and image signing...
Page 60: ...60 Troubleshooting Network integration checklist...
Page 90: ...90 CX x70 Desktop Appliance Specifications CX 570 and CX 770 specifications...
Page 94: ...94 CX x55 Appliance Specifications CX 255 specifications...