Step3.  Set the lens position 

The  device  is  360°  rotating  camera  and  fully  controlled  by  web  user  interface.  Once  the 

unit’s  installation  is  complete  and  connected  properly,  please  refer  to  IPXIPN  Web  User’s 

Manual for the device’s camera configuration instructions.  

Step4. Set up network environment 

The default IP address of the device is 192.168.XXX.XXX. Users can identify the IP address of 

the device from converting the MAC address’s hexadecimal numbers, which is attached to the 

device.  Be  sure  that  the  device  and  PC  are  on  a  same  area  network  before  running  the 

installation. 

 

Generic IP Environment 

In  case  of  generic  private  network  environment  where  IP  address  192.168.XXX.XXX  are 

used, users may view the live streaming images on a web page using the device’s default IP 

address:   

 

1.

 

Convert  the  device’s  MAC  address  to  the  IP  address.  Refer  to  the  Hexadecimal-Decimal 

Conversion Chart at the end of the manual. 

 

(The MAC address of the device is attached on the side or bottom of the device.) 

 

 

 

2.

 

Start the Microsoft® Internet Explorer web browser and enter the IP address of the device.  

 

3.

 

Web streaming and device configurations are supported through ActiveX program. When 

the ActiveX installation pop-up window appears, authorize and install the ActiveX setup.exe, 

               MAC address = 00-13-23-01-14-B1 

 IP address = 192.168.20.177 

 

Convert the last two set of hexadecimal numbers to decimal 
numbers. 

Summary of Contents for RC 4602HD

Page 1: ...RC4602 Ver1 1 www rivatech de Quick Installation Guide RC 4602HD This manual provides instructions for quick installation and basic configuration of your IP device ...

Page 2: ...ing image below Incorrect connection may cause malfunction or damage to the IP device Caution Model design and appearance are subject to change without any prior notice 6 pin Terminal Connect Digital Out 3 5 mm Microphone Stereo Jack 3 5 mm Speaker Stereo Jack Video Out 32 pin socket microSD slot Main Camera Body Top View PCB Top View LAN Cable 3 pin Power Terminal Connect 8 pin Terminal Connect D...

Page 3: ...ign with the main camera body s three unit holders 4 Once cable connect is complete along with brackets and poles on an installation spot align the connector of the cover shield and socket of the main body and then push the main body to conjoin together 5 Once two units are attached rotate the main camera body counterclockwise to secure the lock 6 Insert three screws on top cover shield and tighte...

Page 4: ...on Generic IP Environment In case of generic private network environment where IP address 192 168 XXX XXX are used users may view the live streaming images on a web page using the device s default IP address 1 Convert the device s MAC address to the IP address Refer to the Hexadecimal Decimal Conversion Chart at the end of the manual The MAC address of the device is attached on the side or bottom ...

Page 5: ...istrative tasks which includes network configurations firmware update device reboot and device organizations To modify the device s default IP address for customized network area 1 Find the device from the IPAdminTool s list and highlight the device s name 2 Right click the mouse and select IP Address IP Setup window appears PC environment Info Give new unique IP address in last two sets and mirro...

Page 6: ...orated to the IP Address Subnet Mask Gateway and DNS boxes except the last 2 sets of IP Address which are to be the unique numbers for the device Refer to the image above for the setting 4 Click Setup to complete the modification When the dialog box appears to request user name and password enter the default value for the administrator account case sensitive as ID root Password pass ...

Page 7: ...p up The default username and password is root pass 1 When the browser asks to install the AxUMF software click Install to proceed 2 When Setup installation pop up window appears click install to proceed with rest of installations Note i Depends on system OS and Internet Explorer version Installation experience may differ from one another Figures described above are from Windows 7 Internet Explore...

Page 8: ...ry defaults To reset back to the factory default 1 Press reset button and hold 2 Release the button after 5 seconds 3 Wait for the system to reboot The factory default settings can be inferred as follows More Information To learn more about using other features of your devices refer to the manuals as RIVA Web Interface Manual Full HD Series or VCAsys Online Help which is available on www rivatech ...

Page 9: ...97 EA 234 0D 13 32 50 57 87 7C 124 A1 161 C6 198 EB 235 0E 14 33 51 58 88 7D 125 A2 162 C7 199 EC 236 0F 15 34 52 59 89 7E 126 A3 163 C8 200 ED 237 10 16 35 53 5A 90 7F 127 A4 164 C9 201 EE 238 11 17 36 54 5B 91 80 128 A5 165 CA 202 EF 239 12 18 37 55 5C 92 81 129 A6 166 CB 203 F0 240 13 19 38 56 5D 93 82 130 A7 167 CC 204 F1 241 14 20 39 57 5E 94 83 131 A8 168 CD 205 F2 242 15 21 3A 58 5F 95 84 1...

Page 10: ...RC4602 Ver1 1 www rivatech de 22 34 47 71 6C 108 91 145 B6 182 DB 219 23 35 48 72 6D 109 92 146 B7 183 DC 220 24 36 49 73 6E 110 93 147 B8 184 DD 221 ...

Reviews: