background image

Rittal CMC III transponder reader VX

1  Notes on documentation

 EN

Notes on documentation

1.1  CE labelling

Rittal GmbH & Co. KG hereby confirms that the CMC 

III transponder reader VX is compliant with the EC EMC 

Directive 2014/30/EC. An appropriate declaration of 

conformity has been prepared. It can be provided on 

request.

1.2  Storing the documents

The assembly and operating instructions as well as 

all applicable documents are an integral part of the 

product. They must be passed to those persons who 

are engaged with the unit and must always be avail-

able and on hand for the operating and maintenance 

personnel.

1.3  Symbols used in these operating in-

structions

The following symbols are used in this documentation:

Danger! 

Hazardous situation leading directly to 

death or serious injury if the instruc-

tions are not followed.

Warning!

Hazardous situation which may lead 

directly to death or serious injury if the 

instructions are not followed.

Caution!

Hazardous situation which may lead to 

(minor) injuries if the instructions are 

not followed.

Note:

Identification of situations that can lead to 

material damage.

 

◾ This symbol indicates an "action point" and shows 

that you should perform an operation or procedure.

1.4  Associated documents

 

– Installation and Short User Guide

 

– Assembly and operating instructions for compatible 

base systems, e.g. CMC III Processing Unit

Note:

Additional compatible base systems can be 

found on the internet at www.rittal.com for 

model no. DK 7030.233. The term "base 

systems" is used in these instructions as 

placeholder for the various systems.

 

– CMC III Access Control/Door Control Module (DCM) 

assembly and operating instructions

Summary of Contents for CMC III VX

Page 1: ...Assembly and operating instructions CMC III transponder reader VX DK 7030 232 DK 7030 233 ...

Page 2: ...rred to hereafter as transponder reader We wish you every success Yours Rittal GmbH Co KG Rittal GmbH Co KG Auf dem Stuetzelberg 35745 Herborn Germany Tel 49 0 2772 505 0 Fax 49 0 2772 505 2319 E mail info rittal de www rittal com www rittal de We are always happy to answer any technical questions regarding our entire range of products ...

Page 3: ... 5 2 Siting location requirements 8 5 3 Installation procedure 8 5 3 1 Installation note 8 5 3 2 Installation on a VX and VX IT sheet steel door 8 5 3 3 Installation on a VX glazed door 8 5 3 4 Installation on a VX IT glazed door or VX IT vented door 9 5 4 Connecting the transponder reader 9 6 Operation 10 6 1 Activating the transponder reader 10 6 2 Operating and display elements 10 6 3 LED displ...

Page 4: ...er Hazardous situation leading directly to death or serious injury if the instruc tions are not followed Warning Hazardous situation which may lead directly to death or serious injury if the instructions are not followed Caution Hazardous situation which may lead to minor injuries if the instructions are not followed Note Identification of situations that can lead to material damage This symbol in...

Page 5: ...ues stated must not be exceeded under any circumstances In particular this applies to the specified ambient temperature range and IP degree of protection The transponder reader may only be opened for mounting purposes The unit does not contain any parts that need servicing Operating the system in direct contact with water aggressive materials or inflammable gases and va pours is prohibited Other t...

Page 6: ...sing transponder cards It may be used only together with the CMC III Processing Unit CMC III Access Control or Door Control Module DCM Any other use is not permitted The unit is state of the art and built according to rec ognised safety regulations Nevertheless incorrect use may result in damage to or faults with the system and other material assets Consequently the unit must only be used properly...

Page 7: ...r unpacking the packaging materials must be disposed of in an environmentally friendly way They consist of the following materials Polyethylene film PE film cardboard Check the unit for any damage that may have oc curred during transport Note Damage and other faults e g incomplete delivery should be reported immediately in writing to the shipping company and to Rittal Remove the unit from the PE f...

Page 8: ... 3 Installation procedure There are generally several options for installing the transponder reader Installation on a VX and VX IT sheet steel door Installation on a VX glazed door Installation on a VX IT glazed door or VX IT vented door 5 3 1 Installation note Cover the area around where holes are to be drilled before drilling in order to prevent damage and scratches 5 3 2 Installation on a VX an...

Page 9: ...cation using the flat headed screws provided Finally reattach the locking bars 13 37 5 KB 40x30 MA 2 5 Nm Ø4 5 Ø8 166 23 Ø9 4x90 Ø4 5 Option Fig 4 VX IT glazed door VX IT vented door installation 5 4 Connecting the transponder reader Note The transponder reader is compatible with the CMC III Access Control DK 7030 202 and the Door Control Module DCM DK 7030 501 The Access Control DCM supplies the ...

Page 10: ...rea To add a new transponder card Hold the transponder card in front of the transponder reader before selecting the Access Configurations dialogue Regardless of the next work steps In the Security group frame click on the Access Configuration button The Access Configurations dialogue opens To configure a transponder card Select the line with the required entry to change the configurations stored f...

Page 11: ... III Processing Unit from a PC see the assembly and operating instructions for the CMC III Processing Unit In the left hand subwindow PC switch to the folder where you wish to locally save the access cmc3 file Switch to the upload folder in the right hand sub window CMC III PU Right click the access cmc3 file and select the Download action Disconnect the S FTP connection between the PC and CMC III...

Page 12: ...ster with their tran sponder cards or their number code Tab 5 Time interval for the four eyes principle Assignment of reader units to access modules The lines for the assignment of reader units to access codes contain the following entries Parameter Explanation Keypad Serial number of the Access Control or the virtual access controller to which the reader unit is connected with the following assig...

Page 13: ...e is not used for a long period Rittal recom mends that it be disconnected from the mains power supply and protected from damp and dust 7 2 Disposal Since the transponder reader consists mainly of the housing and circuit board parts the device must be passed on to the electronic waste recycling system for disposal ...

Page 14: ...dity range 5 95 relative humidity non condensing Protection category IP 40 to IEC 60 529 Technology Transponder 13 56 MHz The following tags can be read ISO 14443A Mifare Legic Advant HID FeliCa Legic Prime on request Detailed information can be found in the internet at www rittal de for model no DK 7030 232 or DK 7030 233 Frequency 13 56 MHz Connection cable m 2 9 Inputs and outputs Interface for...

Page 15: ...service addresses EN 9 Customer service addresses For technical queries please contact Tel 49 0 2772 505 9052 E mail info rittal de Homepage www rittal com For complaints or service requests please contact Tel 49 0 2772 505 1855 E mail service rittal de ...

Page 16: ...ftware Services RITTAL GmbH Co KG Auf dem Stuetzelberg 35745 Herborn Germany Phone 49 2772 505 0 E mail info rittal de www rittal com www rittal com contact You can find the contact details of all Rittal companies throughout the world here 10 2019 D 0000 00002250 00 EN ...

Reviews: