6 Troubleshooting
Ritta l S22 insulation stripping machine
We reserve the right to make technical m odifications.
15
EN
6.2
No start for inserted wire
Start sensor (S1) is blocked with stripped insulation scrap.
◼
Press the "Manual cycle" touch display briefly.
Wire inserted incorrectly.
◼
Insert the wire as described in section 4.7 "Wire entry".
6.3
Larger number of rejects
The stripped insulation scrap container is full.
◼
Empty the stripped insulation scrap container.
Cross-section setting button adjusted.
◼
Check the setting
Insulation stripping blade damaged or installed incorrectly.
◼
Repair or replace blade.
6.4
Error messages
Flashing error messages in the touch display.
◼
To acknowledge, press the touch display briefly.
Symbol
Description
Stop switch fault
The Stop switch does not switch or remains pressed.
Start switch fault
Start switch not free.
Motor fault
The motor does not run or jams (current too high).
Service message
Service quantity attained.