7 Cleaning and maintaining the automatic machine
22
We reserve the right to make technical modifications
Rittal crimping machine R8-I
EN
Fig. 12:
Insulation stripping unit
◼
Clean the area around the hole (fig. 12, item 1) with a brush.
◼
If required, use a soft cloth and methylated spirits.
◼
Check the cutters (fig. 12, item 2). If required, replace the blades (see section 8.3
"Replacing the insulation stripping blade").
7.7
Maintaining the crimping tool
To reach the crimping tool, you must dismantle the stranded wire fixing unit.
◼
Ensure that the stranded wire fixing unit is at the front position (fig. 11, item B).
◼
Remove the right lower screw of the stranded wire fixing unit (fig. 11, item 4).
◼
Remove the stranded wire fixing unit forwards carefully.
◼
Tilt the stranded wire fixing unit to the side and place it down carefully.
Fig. 13:
Stranded wire fixing unit dismantled
2
2
1