Section 4
Operation
31
Connecting the Relay Switch to a Strobe Light
1. A simple switch closure capable of handling 3A current.
The strobe light is activated when two On/Off inputs are connected.
The strobe light requires its own external power, either AC or DC.
Interface Cable
Description
Strobe Light
Blue
Common Switch Contact
On/Off Switch
Green
Normally Open Switch Contact
On/Off Switch
Red
+10.5VDC, 400mA MAX
No Connection
Black
Ground
No Connection
2. A switch closure to ground to activate.
The strobe light is activated when a single On/Off input is pulled to ground.
The strobe light requires its own external power, either AC or DC.
Interface Cable
Description
Strobe Light
Blue
Common Switch Contact
On/Off Switch
Green
Normally Open Switch Contact
Connect to Black wire
Red
+10.5VDC, 400mA MAX
No Connection
Black
Ground
Connect to Green wire
3. A switch opens to release from ground to activate.
The strobe light is activated when a single On/Off input is released from ground.
The RIB-600Analog relay must be configured for normally-closed operation. Refer to
section 2.8 Installation of Optional Interface Cable Assembly 60201136.
The strobe light requires its own external power, either AC or DC.
Interface Cable
Description
Strobe Light
Blue
Common Switch Contact
On/Off Switch
Green
Normally Closed Switch Contact
Connect to Black wire
Red
+10.5VDC, 400mA MAX
No Connection
Black
Ground
Connect to Green wire
4. Using the switch to connect 10.5 VDC from the RIB-600Analog.
This allows a strobe light to be DC powered by the RIB-600Analog when the relay is closed.
The strobe light must be able to operate on +10.5VDC, and requires 400mA or less.
Interface Cable
Description
Strobe Light
Blue
Common Switch Contact
Power Supply (+)
Green
Normally Open Switch Contact
Connect to Red wire
Red
+10.5VDC, 400mA MAX
Connect to Green wire
Black
Ground
Power Supply (-)
5. A switch closure to ground to activate, with 10.5 VDC from the RIB-600Analog to power the strobe.
The strobe light is activated when a single On/Off input is pulled to ground.
The strobe light must be able to operate on +10.5VDC, and requires 400mA or less.
Interface Cable
Description
Strobe Light
Blue
Common Switch Contact
On/Off Switch
Green
Normally Open Switch Contact
Connect to Black wire
Red
+10.5VDC, 400mA MAX
Power Supply (+)
Black
Ground
Power Supply (-)
Power Supply (+)
Power Supply (-)
On/Off Switch
Power Supply (+)
Power Supply (-)
On/Off Switch
Power Supply (+)
Power Supply (-)
On/Off Switch
On/Off Switch
Power Supply (+)
Power Supply (-)
On/Off Switch
Power Supply (+)
Power Supply (-)