Section 3
Programming
13
3
Programming
For some installations the RIB-600Analog can be programmed in the field without the need
for the Ritron PC Programmer LM-PCPS (LM-PCPK-USB kit with cable).
Field programming
is accomplished in 3 easy steps. First, the radio frequency and tone codes are entered.
Second, the selective signaling code is entered (if used). Third, the RIB-600Analog options
and audio level setting are entered.
3.1
PC Programming Software LM-PCPS
While most RIB-600Analog programming can be accomplished via Field Programming, the Ritron PC Programming Software (LM-PCPS) can also
be used. The PC Programmer allows viewing of all programmed attributes at once. It also permits you to save a programming profile you can use to
easily program other RIB-600Analog radios to the same settings. Ritron PC Programming kit LM-PCPK-USB includes the LM-PCPS programming
software and a USB Programming cable.
3.2
RIB-600Analog Field Programming Overview
Program
Codes
Table Codes
Readout Frequency programming
or
Enter a Frequency code from
T
ABLE
F:
P
ROGRAMMABLE
F
REQUENCY
T
ABLE
or
Enter any valid frequency from 150-174 MHz, or from 450-470 MHz
Readout QC or DQC Tone programming
or
Enter a 2-digit Quiet Call code from
T
ABLE
b:
P
ROGRAMMABLE
QC
T
ONE
T
ABLE
or
Enter a 3-digit Digital Quiet Call code from
T
ABLE
b:
P
ROGRAMMABLE
D
IGITAL
DQC
T
ONE
T
ABLE
Readout 2-Tone, Selcall or DTMF decode programming
or
Enter a 2-digit, 2-Tone Paging code from
T
ABLE
C:
P
ROGRAMMABLE
2-T
ONE
,
DTMF
AND
S
ELCALL
C
ODES
or
Enter
1
plus any 3
–7 digit DTMF Code
or
Enter
2
plus any 3
–7 digit Selcall Code
Enter a 2-digit or 3-digit RIB-600Analog Feature code from
T
ABLE
A:
A
DVANCED
F
EATURE
C
ODES
to:
Enable or disable a Pre-Announce Tone
Set a Record and Play delay time
Set to repeat a Record and Play message
Enable or disable Weather Alert feature
Set the RIB-600Analog for wideband operation
Enable or disable Relay operation
Set a minimum Relay activation time
Reset RIB-600Analog to Factory default programming
Set the RIB-600Analog to play a pre-recoded Switch ON
and/or Switch OFF message on Switch Input detection
Readout the programmed Audio level
or
Enter the desired Audio Level as a 2-digit number from 05-99%.
Readout the programmed NOAA Weather Frequency code
or
Enter the 1-digit NOAA Weather Frequency code from
T
ABLE
d:
NOAA
W
EATHER
F
REQUENCY
C
ODES
NOTE:
This only programs the NOAA weather frequency, the Weather Alert feature must be enabled using the code in
T
ABLE
A:
A
DVANCED
F
EATURE
C
ODES
Place the RIB-
600Analog
receiver into
Program
mode.
Use
PROGRAM
button
to scroll to one of the
following 6 Program
Code characters:
F, b, C, A, U, d
Pause
, a
hyphen
will appear
on the
display.
Using the
PROGRAM
button, enter
the desired
Table Code.
Press
ENTER
button to save
programming entry.
Press
ENTER
button a second time
to Exit programming.