ritetemp 8082C Operation Manual Download Page 8

PG

 13

PG

 14

RE

SE

T

1   2

   3

NOTE: 

The remote control system for the 8082c operates on external "C" wire power only. The 

thermostat must be connected to the "C" wire or a 24vac power source for the remote to function.  If 
your unit is operating on Batteries only, then the remote function is disabled to protect battery life.

Remote Control

Set Channel on Remote-

ï To set the channel of the remote, slide the CHANNEL switch to 

your desired channel number.

Set Channel on the main unit-

ï To set the channel of the main unit, press MENU and touch "CH" 

to select the same channel number as the remote and then touch "HOME".

Temporary temperature override -

ï With the Mode switch of the main unit in HEAT or COOL and the unit at the 

HOME

 screen,

ï When the 8082C recieves a remote command for a 

TEMPORARY

 adjustment, The 

MANUAL OVERRIDE screen comes on showing the new target temperature, and the 

temporary icon will be blinking.  After about 15 seconds, the home screen will return 

showing the room temperature and the new target temperature.

The remote beeps to let you know it is working. The main unit beeps when it recieves a 

remote command. The 

TEMPORARY

 icon comes on which shows the displayed Target 

Temperature is different from the programmed setting.

To cancel the Remote temperature overrides -

ï Press the remote's "RESET" button once. The main unit will return to its program.

Temp up

button

Channel 

selector

Temp down

 button

Temp reset 
button

RE

SE

T

1   2  

 3

CHANNEL

Beep Pattern 

The remote beeps once and then 3 seconds 
later beeps 1,2,or 3 times (depending on 
channel selection) and sends the signal.  The 
thermostat beeps when it receives the signal.

Note:

 The unit sends a one degree increment 

for each time you press the

 UP

 or 

DOWN

 

arrow on the remote. Pressing the remote 
once per 3 second interval gives the unit time 
to respond to your command. Faster pressing 
can give unreliable results.

A23

A23

A23
(MN21)

To Replace Batteries in the remote -

Open the compartment as shown. Insert the A23 (MN21) size 
battery as shown  and then replace the  cover closed.

AUTO Switching

In the AUTO mode, the 8082C will automatically change from heat to 

cool as necessary.  The AUTO uses the HEAT program for heating and the COOL program 

for cooling.  

NOTE: 

If 

TEMPORARY

 or 

HOLD

 is used, the AUTO switching function is disabled.

Summary of Contents for 8082C

Page 1: ...Customer Support 888 515 2585 or Visit our webiste www ritetemp thermostats com Printed in China 1 402 012 RESET MENU PROGRAM RESET 1 2 3 ENGLISH Operation 8082C RESET MENU PROGRAM RESET 1 2 3...

Page 2: ...rent Room Temperature Remote Control Channel Indicator Chirp indicator Target Temperature TARGET TEMP Please take a moment to try out your touch screen itself To select a function place your finger on...

Page 3: ...f the week you want to program Target Temps for Set Time Slot Touch this area to set the Time Slot you want to program Set Program Time Touch this area to set the time of day you want each time period...

Page 4: ...IME SLOT active in the Energy Star Tm program The programmed temperature is shown on the lower right For program details refer to the Energy Star TM program chart below All Days 70 o F 62 o F 70 o F 6...

Page 5: ...until it displays the desired time COOL times will be the sames as these HEAT times Forward Backward Select the desired temperature Touch the UP temp Down temp arrows Repeat the above procedures for e...

Page 6: ...the Manual override screen Touch HOLD to a hold temperature Touch the Temp Up Temp Down arrows to select your hold temp Touch HOME to return to operation The HOLD icon will flash indicating you have c...

Page 7: ...AA Batteries in the unit need to be replaced In some installations your heater system will stop functioning when the thermostat loses power Replace batteries as soon as you see this warning The therm...

Page 8: ...u know it is working The main unit beeps when it recieves a remote command The TEMPORARY icon comes on which shows the displayed Target Temperature is different from the programmed setting To cancel t...

Page 9: ...built in humidifier and HEAT mode This thermostat can be used to humidify by turning on a humidifier in the furnace Connect the H terminal on the 8082C to the humidifier control relay To set the MIN...

Reviews: