1 Location
Caution
Tools
To avoid electrical shock and to prevent damage heating system,
and thermostat, disconnect the power supply before beginning work.
This can be done at the circuit breaker, or at the appliance.
• On replacement installations, mount the new thermostat in
place of the old one.
• On new Installations, follow the guidelines listed below.
Locate the thermostat on an inside wall, about 5 ft. (1.5m) above
the floor, and in the room with the heater to be controlled.
• Do not install where there are unusual heating conditions, such
as: in direct sunlight; near a lamp, radio, television, or above the
baseboard heater, or fireplace; near hot water pipes in a wall; or
any other heat source.
• Do not locate in unusual cooling conditions: in a draft from a
stairwell, door, or window; or on the wall of an unheated room.
• Do not locate in a damp area. This can lead to corrosion that
will shorten thermostat life.
• Do not locate where air circulation is poor, such as: in a corner
or an alcove; or behind an open door.
• Do not install until construction and painting is completed.
• This thermostat does not require leveling.
You will need #1 Phillips screwdriver (small)
PG
1
C A U T I O N
•
Your thermostat is a precise instrument.
•
Please handle it with care.
•
Turn off electricity to the appliance before installing or
servicing thermostat or any part of the system. Do not
turn electricity back on until work is completed.
•
Do not short (jumper) across electric terminals at
control on furnace to test the system. This will damage
the thermostat and void your warranty.
•
All wiring must conform to local codes and
ordinances.
•
This thermostat is designed for use with 120-220 volt
AC systems. The thermostat should be limited to a
maximum of 16.0 amps; higher amperage may cause
damage to the thermostat.
PG
2
Good
5ft.
(1.5m)
Install Guide 8045