background image

Publication: 

AMEN00393 2020-07-06 

PUB. NO. VGRDG  JANUARY 2015

9

VERTIGUARD

MAINTENANCE & TROUBLESHOOTING

POWER / STARTUP

1. Turn power on to the control box.
2. Turn on air supply.
3. Press the close button, the curtain will slide to the

extended position.

MONTHLY MAINTENANCE PROCEDURES

1. Visually inspect the Vert-Guard panel during an

open and close cycle to verify proper operation and

that door is fully opening and closing.

2. Clean the panels with a warm soapy solution.
3. Inspect all air, electrical, and mounting hardware

connections and make sure all connections are

tight.

4. Inspect all parts for signs of wear and replace as

necessary.

5. Check aluminum track for debris buildup. 

Clean if necessary. Check guides for wear.

6. Apply Lubriplate to panel wear pads as needed.

DEFINITION

FUNCTION

Cylinder

The cylinder extends and retracts the panel in the opening when air is supplied.

Frame Assembly

The frame assembly is an all aluminum structure which holds the cylinder, panel guides and air hose. 

Control Box Assembly

The control box assembly includes a four way air control valve, open, close and stop push buttons, and 

(optional)

(2) 24 VDC relays. This control box allows the VertiGuard to be opened or closed by momentarily 

pushing a button, or from a 24 VDC output signal from a machine controller. This box requires use of a 

110 VAC air valve.

Junction Box Assembly The Junction box assembly includes a four way air control valve, and the necessary terminal blocks to 

(optional)

easily incorporate an output signal from the existing machine controller. The four way valve is available as

24 VDC or 110 VAC.

Panels

The panels are made of either painted or galvanized sheet metal.

Panel Does Not Close

a) Check air hose connections for a tight secure fit and for air hose leak.

b) Replace air hose.

Panel Jerks

a) Guide wear pads loose or worn out, check hardware or replace as required.

b) Excessive build up of debris in track. Use an air nozzle to clear debris from the track.

Summary of Contents for VERTIGUARD

Page 1: ...ion No VGRDG email printshop RITEHITE com January 2015 This manual to remain with the unit Date Installed ____________________ VERTIGUARDTM AUTOMATED SAFETY BARRIER This Manual Covers All Units Shippe...

Page 2: ...edures for the installation operation or maintenance of the VertiGuard have been left out of this manual or are not understood contact Technical Support at 1 563 589 2722 SITE EVALUATION The VertiGuar...

Page 3: ...ause severe personal injury death WARNING Caution indicates the presence of a hazard that will or can cause minor personal injury death CAUTION Notice communicates installation operation or maintenanc...

Page 4: ...pulled in or spread out causing undue wear and friction on the panel wear guides and the side rail track 6 Side rails must be parallel in both front and side directions Shimming may be required on th...

Page 5: ...Publication AMEN00393 2020 07 06 5 VERTIGUARD PUB NO VGRDG JANUARY 2015 5 INSTALLATION INSTRUCTIONS F Figure 3 2...

Page 6: ...ounting Bracket G Front Rear Mounting Bracket H Side Mounting Bracket K Sliding Panel L Pneumatic Cylinder M Rear Upper Cylinder Guard N Lower Cylinder Support Brace P Stationery Lower Panel Back Cove...

Page 7: ...n route the main air line through the pressure regulator provided Maintain an operating pressure between 60 and 90 psi 4 Connect an air line from the outlet of the pressure regulator to the inlet C of...

Page 8: ...erminal block LIMIT SWITCH CABLE 7 White wires to 7 terminal block 6 Close limit switch black wire to 6 terminal block for normally open or normally closed limit switch or 5 Open limit switch black wi...

Page 9: ...ame Assembly The frame assembly is an all aluminum structure which holds the cylinder panel guides and air hose Control Box Assembly The control box assembly includes a four way air control valve open...

Page 10: ...HECKED BY MATERIAL PART NO R C A 5220E004 RITE HITE DOORS INC 1 1 SLIDE AIR JUNCTION BOX WIRING DIAGRAM 110 VAC 1370 53530004 6 25 1996 2833 3 15 2000 2000 5 MC1 35 5 TERMINAL BLOCK COMPONENT NAME ASS...

Page 11: ...24 VDC CLOSE COMMAND 6 OPEN PROX COMMON 5 7 CLOSE PROX TO END USER CONTROL SYSTEM OPTIONAL WIRING FROM DISCONNECT OPEN PROX N O BLACK WIRE N C RED WIRE OPEN PROX N O BLUE WIRE N C GREEN WIRE PROX COMM...

Page 12: ...TEM QTY DESCRIPTION P N 27 2 Tab Mount Siderail 72740039 28 2 Tab Mount Lower Support Brace 72740040 29 a r Nut Hex 1 4 20 znc 55610002 30 a r Nut Tee 1 4 20 55610017 31 a r Nut Hex 3 8 16 znc 5563000...

Page 13: ...y 51000002 12 1 Fuse Holder 1 Pole 300V 12A 51000004 13 1 Muffler Pneumatic ASP2 55280000 ITEM QTY DESCRIPTION P N 14 2 Relay DPDT 24VDC 5 amp 66450010 15 1 Socket Relay 2 Pole 250V 5 amp 70350001 16...

Page 14: ...5 67 1 5 9 1 67 237 21 67 32 5 2 7 2 25 2 5 5217 3 1 0 7 5 67 1 5 9 1 67 237 21 67 32 5 2 7 2 25 237 21 2 5 3 1 0 7 5 67 1 5 9 1 67 237 21 67 32 5 2 7 2 25 237 21 1 5 29 5 0 7 5 67 1 5 9 1 67 237 21 6...

Page 15: ...0 7 5 67 1 5 9 1 67 237 21 67 32 5 2 7 2 25 237 21 2 5 3 1 0 7 5 67 1 5 9 1 67 237 21 67 32 5 2 7 2 25 237 21 1 5 29 5 0 7 5 67 1 5 9 1 67 237 21 67 32 5 2 7 2 25 1 5 25 28 7 1 8720 7 867 1 86 21 1 26...

Page 16: ...itehite com machineguard www ritehite com RITE HITE MACHINE GUARDING WARRANTY 16 PUB NO VGRDG JANUARY 2015 VERTIGUARD LIMITED WARRANTY RITE HITE Company LLC and its affiliates collectively RITE HITE w...