background image

SAFETY WARNINGS

This is the highest level statement. Failure to

follow the listed instructions will most likely

result in severe injury or death.

D A N G E R ! ! !

!

The statements used with this level of 

warning deal with a safe operating 

procedure. If the procedure is ignored, the

possibility of personal injury may exist.

C A U T I O N ! ! !

!

This is a statement of serious hazard. Failure to

follow the listed instructions could place the

individual at risk of serious injury or death.

WA R N I N G ! ! !

!

IMPORTANT is used to draw attention

to a procedure that needs to be followed to

prevent machine or property damage.

I M P O R TA N T ! ! !

SAFETY WARNINGS

When working with electrical or electronic

controls, make sure that the power source has

been locked out and tagged according to OSHA

regulations and approved local electrical codes.

WA R N I N G ! ! !

!

LOCKOUT/TAGOUT PROCEDURES

The Occupational Safety and Health Administration requires that, in addition to posting safety warnings and
barricading the work area, the power supply has been locked in the OFF position or disconnected. It is mandatory
that an approved lockout device is utilized. An example of a lockout device is illustrated above. The proper lockout
procedure requires that the person responsible for the repairs is the only person who has the ability to remove the
lockout device.

In addition to the lockout device, it is also a requirement to tag the power control in a manner that will clearfspy note
that repairs are under way and state who is responsible for the lockout condition. Tagout devices have to be
constructed and printed so that exposure to weather conditions or wet and damp locations will not cause the tag to
deteriorate or become unreadable.

RITE-HITE

®

does not recommend any particular lockout device, but recommends the utilization of a device that

meets OSHA standards (refer to OSHA regulation 1910.147). RITE-HITE

®

also recommends the review and

implementation of an entire safety program for the Control of Hazardous Energy (Lockout/Tagout). These regulations
are available through OSHA publication 3120.

REVOLUTION SP FAN

Pub. No. RFSP Rev. 5 - December 2010   

3

Summary of Contents for REVOLUTION SP

Page 1: ...INSTALLATION AND OWNER S MANUAL PRINTED IN U S A PUBLICATION NO RFSP REV 5 RITE HITE PRINT SHOP DECEMBER 2010 This Manual Covers All Fans Shipped 1 07 to Date...

Page 2: ...the Planned Maintenance Program P M P which can be fitted to your specific operation Call your local representative or RITE HITE at 1 414 355 2600 or toll free at 1 800 456 0600 The RITE HITE product...

Page 3: ...ing the work area the power supply has been locked in the OFF position or disconnected It is mandatory that an approved lockout device is utilized An example of a lockout device is illustrated above T...

Page 4: ...ave received all of the above items before installation begins Notify the factory if parts are missing or damaged TOOLS REQUIRED 2 7 16 wrenches 2 wrenches 1 1 box end wrench 1 1 1 16 box end wrench 2...

Page 5: ...reas when the fan is running Whenever possible allow 12 additional clearance to IMPORTANT If the ceiling support structure is an open web design all hanging dimensions can be taken from the underside...

Page 6: ...Use a level to ensure the extension tube is hanging vertical CEILING TRUSS MOUNTING STRUCTURAL ANGLES Never mount the fan to only one building joist One joist will not provide the rigidity and suppor...

Page 7: ...plied by Rite Hite is designed to make the installation of the kit easier The two formed angles span existing building trusses The drawing below shows how the brackets are used to secure the angles to...

Page 8: ...e 3 x 3 tube should always bolt to the ceiling bracket If the fan assembly is mounted directly to the ceiling bracket without an extension tube you will need to purchase 4 x grade 8 bolts locally to b...

Page 9: ...r object For the most support possible attach the cables to the ceiling at 90 degrees to each other and as far away from the point where the fan is mounted as possible These cables are secured at the...

Page 10: ...to 75 ft lb 102 NM Clean each blade with a paper towel to remove fingerprints and dirt before the blades are installed In the event a blade is damaged the damaged blade and the blade opposite must be...

Page 11: ...o open the relay will stop the fan REMOTE STOP FOR OPEN AIR ENVIRONMENT When fans are used in open air environments it may be necessary to shut the fans down as wind speed increases These controls can...

Page 12: ...or another controller MAY NOT share the same conduit The conduit with the incoming power and the conduit with the power going to the motor should be separated by a minumun of 6 152 mm Do not use soli...

Page 13: ...REVOLUTION SP FAN Pub No RFSP Rev 5 December 2010 13 CONTROL BOX WIRING...

Page 14: ...REVOLUTION SP FAN 14 Pub No RFSP Rev 5 December 2010 STOP CURCUIT FOR MULTIPLE FANS SCHNEIDER ELECTRIC...

Page 15: ...REVOLUTION SP FAN Pub No RFSP Rev 5 December 2010 15 REMOTE MOUNTED FAN FOR SCHNEIDER ELECTRIC...

Page 16: ...omer RECOMMENDED FUSE RATINGS Recommended Branch Recommended Circuit Protection Incoming Service Input Voltage Amps Amps 110 120V 1PH 60 Hz 20A 20A 200 240V 1PH 60 Hz 15A 15A 200 240V 3PH 60 Hz 15A 10...

Page 17: ...the master frequency drive will restart the frquency drive only Cycle the remote on off switch to restart all fans Ceiling mounted standard control boxes should not be mounted inside the fan diameter...

Page 18: ...IONAL The laminated beam brackets are through bolted with one bracket on each side of the laminated or concrete beam The standard ceiling mounting bracket should then be attached to this bracket in th...

Page 19: ...n Do not use strong solvents FAN MOUNTING Re torque all fasteners 1 2 13 Grade 8 98 ft lbs 5 16 18 Grade 8 29 ft lbs Check the fan including mounting supports to make sure all hardware is tight and sh...

Page 20: ...ple will detect It is caused by the frequency drive creating power for the fan motor and it will always be present with a motor that is controlled by a variable frequency drive 3 Wind noise will be pr...

Page 21: ...switch Check for loose jumper wire between terminals 1 and 11 on frequency drive Stop signal from fire protection system If fan is wired to shut off with fire protection system verify that fan is not...

Page 22: ...6100 mm 29 rpm 16 fan 4880 mm 35 rpm 12 fan 3660 mm 50 rpm 8 fan 2440 mm 75 rpm If the fan rotates at a different speed than above check the gearbox label to insure the wrong size blades were not ins...

Page 23: ...ket Assembly includes the following parts White 135144 1 Ceiling Mount Bracket White 135145 2 Spacer White 135146 2 Clamp Plate White 125338 4 Bolt 5 13 x 2 Grade 8 125339 6 Nut 5 13 Nylock Grade 8 12...

Page 24: ...ube 135129 2 Top Angle Black 125338 4 Bolt 5 13 x 1 5 Grade 8 125339 6 Nut 5 13 Nylock Grade 8 125340 2 Bolt 5 13 x 4 5 Grade 8 51709 8 Washer 5 Flat 125337 2 Top Angle GREY 4 Bolt 5 13 x 1 5 Grade 8...

Page 25: ...olished 135160 4 Clevis Cover Painted Dome Hub Cover 135161 1 Dome Hub Cover Painted to match Annodize 135283 1 Dome Hub Cover Painted to match MILL FINISH 135162 1 Dome Hub Cover Plated to match Poli...

Page 26: ...4 1 1 HP 110 120 V 1 PH 60 Hz 135185 1 1 HP 208 240 V 1 PH 60 Hz 135186 1 1 HP 208 240 V 3 PH 60 Hz 135187 1 1 HP 460 480 V 3 PH 60 Hz 135188 1 1 HP 575 V 3 PH 60 Hz 135189 1 1 HP 208 240 V 1 PH 50 Hz...

Page 27: ...5 stabilization cable attachment white 125368 5 Bolt 5 13 x 5 0 Grade 8 125339 5 Nut 5 13 Nylock Grade 8 51709 6 Washer 5 Flat 125365 1 4 7 Down Tube Assembly Includes the following parts grey 125366...

Page 28: ...st Fan includes the following parts white 135269 2 Angle 4 625 x 3 x 1875 x 120 white 2 Bolt 5 13 x 10 fully threaded grade 8 51709 4 Washer 5 Flat 125339 2 Nut 5 13 Nylock Grade 8 135270 2 Bracket Sp...

Page 29: ...REVOLUTION SP FAN Pub No RFSP Rev 5 December 2010 29 NOTES...

Page 30: ...REVOLUTION SP FAN 30 Pub No RFSP Rev 5 December 2010 NOTES...

Page 31: ...REVOLUTION SP FAN Pub No RFSP Rev 5 December 2010 31 NOTES...

Page 32: ...HITE exclusive warranty RITE HITE EXPRESSLY DISCLAIMS ALL IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS Non standard RITE HITE warranties if any must be specified...