background image

Manual Part #:

 54450031

Model:

 REVOLUTION, ROGUE

Publication:

 AMEN00064 2019-03-07

Revolution

®

 HVLS Fan

Rogue

®

 HVLS Fan

Installation/Service/Owner's Manual

This manual covers units shipped February 2019 to date.

Language:

 English  

(Hazards: English, French)

NOTICE TO USER

                             2

SAFETY 

                                       2

INSTALLATION

Components                                   4

Required Tools                                  4

Specifications

                                 4

Fan Clearance, Air Intake                        5

Step 1 – Mounting Preparation                     6

Step 2 – Mounting                              6

Step 3 – Motor Bracket                           9

Step 4 – Safety Cables

  (INCLUDED WITH KIT)

       10

Step 5 – Stabilization Cables

  (INCLUDED WITH KIT)

   11

Step 6 – Attach Blades                            11

Step 7 – Level Hub                              11

Step 8 – Fan Electrical Installation

 (TYPICAL)

         12

Step 9 – Control Box                           13

Step 10 – Label Plate                            13

Step 11 – Motor Cover                           13

Fan Guarding                                 13

ELECTRICAL

Motor Wiring                                  14

Conduit Restrictions                            14

Control Box Wiring                             15

EMC Compliance 

(OPTIONAL)

                     16

MAINTENANCE

Planned Maintenance                          17

TROUBLESHOOTING

Run / Test                                    17

Motor                                        18

PARTS

Mounting                                    20

Extension Tube Assemblies, Cables                21

Motor Cover, Motor Assembly                     22

Blades                                      22

Hub                                        22

Controls 20                                   23

WARRANTY

                                   24

Fan‑Commander 2.0

Required to operate the fan(s) (ordered separately) 
Use Fan‑Commander 20 manual with this manual  

for complete installation and operation instructions

Summary of Contents for Revolution HVLS Fan

Page 1: ...bilization Cables INCLUDED WITH KIT 11 Step 6 Attach Blades 11 Step 7 Level Hub 11 Step 8 Fan Electrical Installation TYPICAL 12 Step 9 Control Box 13 Step 10 Label Plate 13 Step 11 Motor Cover 13 Fan...

Page 2: ...quipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause...

Page 3: ...SI NFPA 70 1999 and local codes L installation doit tre effectu e conform ment au Code national de l lectricit la norme ANSI NFPA 70 1999 et aux codes locaux DANGER A qualified electrician should inst...

Page 4: ...Drill and 1 2in drill bit If mounting to support angles that span building joists Specifications Diameter 8ft 12ft 16ft 20ft and 24ft 2440mm 3660mm 4880mm 6100mm and 7320mm Blades Aluminum Blade Finis...

Page 5: ...Minimum Beam Kit Truss Kit Fan Drop Height 56 5in 1440mm Fan Drop Height 48 00in 1220mm Fan Standard Low Headroom Standard Low Headroom Standard Low Headroom 8ft 2440mm 34in 870mm 36in 920mm 25in 640...

Page 6: ...beam for the hanger dimension If the roof is pitched this must be accounted for above the tips of the blades Fan Weight and Torque NOTICE The weight of the fan that will be suspended from the ceiling...

Page 7: ...e du ventilateur et causer des blessures TYPICAL CEILING TRUSS MOUNTING OPTIONAL LAMINATED BEAM KIT OPTIONAL B B A C D A Angles Support 3in x 3in x 1 4in 75mm x 75mm x 7mm recommended B Building Joist...

Page 8: ...BEAM KIT OPTIONAL 1 Through bolt the laminated beam brackets with 1 bracket on each side of the laminated or concrete beam Figure 4 2 Attach the standard ceiling mounting bracket to this bracket in t...

Page 9: ...and through the extension tube and back through the second angle 3 Tighten both locknuts securely When an extended down tube is used The smaller square tubing 3in x 3in 75mm x 75mm will telescope ins...

Page 10: ...t contre la chute d un ventilateur dans le cas d un rel chement de l assemblage boulonn A B C 1 Wrap a safety cable around the bolted brackets at the ceiling and through the top of the extension tube...

Page 11: ...ecure the stabilization cables to the ceiling with 2 cable clamps and tighten with a turnbuckle 3 Cut stabilization cable to length as required 4 Ensure that stabilization cables are attached in a pos...

Page 12: ...erminated at F1 F2 F3 Fuse Holder Incoming Power from End User Supplied Branch Circuit Fan Motor Disconnect Fan Control Box To Fan Motor Terminal Torque 20lb in Max ACCEPTABLE Unshielded Stranded Cond...

Page 13: ...et so the slotted hole faces outward toward the fan blade c Repeat this process for the remaining 3 brackets 2 Attach the label plate to the label plate brackets a Insert the bolt up through the label...

Page 14: ...r will receive three phase power from the fan control box even if single phase power is provided to the control box Remove the cover from the motor junction box Change the wire leads as necessary for...

Page 15: ...ellow Motor conductors field terminated to VFD terminals using M4 fork connectors provided torque to 1 5Nm NOTE L3 wire and F3 fuse omitted for 230V single phase input option Motor conductors field te...

Page 16: ...llation guidelines Ensure maximum physical separation between low voltage control cables and high voltage power cables minimum 150mm or 6in Ensure maximum physical separation between motor cable and a...

Page 17: ...ck for fraying or wear Gear Reducer Check for oil leaks If leaks are present contact factory Check oil level Add oil if necessary oil type is marked on the gear case Motor Check for dust and dirt Remo...

Page 18: ...fan motor cable from u v w and ground terminals GND 2 Using electrical meter measure resistance ohms between phase wand Phase V Record the 6 resistance values Phase W to V Phase W to GND Phase W to U...

Page 19: ...Publication AMEN00064 2019 03 07 19 Rite Hite Installation Service Owner s Manual Revolution HVLS Fan Rogue HVLS Fan...

Page 20: ...ZNC 12 4 NUT HEX NYL LOCK 1 2 13 GR8 Z 13 2 CABLE AIRCRAFT GLV 1 4 84 14 4 CLAMP CABLE ZINC 1 4 SNGL SAD 6 7 8 9 11 12 10 13 14 TRUSS KIT 55290016 MOUNT ASSY TRUSS FAN GY ITEM QTY DESCRIPTION 6 2 BRK...

Page 21: ...84 9 2 CLAMP CABLE ZINC 1 4 SNGL SAD ITEM 18 30 84 120 DESCRIPTION 1 1 EXTN ASSY FAN 18 GY 2 1 EXTN ASSY FAN 30 GY 3 1 EXTN ASSY FAN 84 GY 4 1 EXTN ASSY FAN 240 GY 5 4 CABLE AIRCRAFT GLV 1 4 120 OR 4...

Page 22: ...SNGL REV 8 DIA LHR 12510057 BLADE SNGL REV 12 DIA LHR 12510058 BLADE SNGL REV 16 DIA LHR 12510059 BLADE SNGL REV 20 DIA LHR 12510060 BLADE SNGL REV 24 DIA LHR DESCRIPTION PART STANDARD HEADROOM BLADE...

Page 23: ...00026 or Filter EMC YSKW 240V 1PH 20A 45500023 2 INV YSKW 240V 3PH 10A 53300081 or INV YSKW 480V 3PH 05A 53300082 or INV YSKW 480V 1PH 10A 53300080 3 PCB RADIO 900MHZ VFD 16650014 or PCB RADIO 2 4MHZ...

Page 24: ...ner s premises for the purpose of repairing or replacing the Product or y return of the Product to the Rite Hite F O B Rite Hite s factory NOT WARRANTED Rite Hite does not warrant against and is not r...