17
STATE
POSITION
Dock Level (Or Lower) End Loading
1 Activate the leveler by pushing and holding the
RAISE button until leveler is fully raised and lip
begins to extend
NOTE:
Some levelers may be equipped with a
2 button control box If so, push and hold the RAISE
button until the lip clears the lip keepers While
pressing the RAISE button, push the LIP EXTEND
button briefly to extend the lip beyond the lip keepers.
2 When lip extends about 2 in (51 mm), release RAISE
button The leveler will lower to the below dock
position with the lip positioned between the face of
the loading dock and the truck/trailer bed
NOTE:
• Some levelers may be equipped with a 2 button
control box If so, release RAISE and LIP EXTEND
buttons
• End load at dock level and above can be handled
with the leveler in its stored position
• If the lip extended too far, quickly push and release
the RAISE button to slightly retract the lip If the
lip was not extended far enough and hits the lip
keepers, repeat this step allowing the lip to extend
farther
3 When loading/unloading is complete, continue with
normal operation or return the leveler to stored
position See
Storing Leveler
1 To store the leveler, push and hold the RAISE button
until leveler is about 6 in (152 mm) above dock level
and lip is fully pendant
2 Release RAISE button Leveler will lower to dock
level with lip resting in the lip keepers
NOTE:
On Powered levelers with ARTD: If the lip is
on the truck/trailer and the truck departs, the leveler
will move to its lowest position and the lip will begin
to lower As the lip drops toward the pendant position,
the ARTD system automatically returns the leveler to
the stored position without operator assistance