3.1.2.4 Bent Function Selection
This screen allows the user to enable or disable the bent characteristics function.
This is applicable only to Normal meter type, and not to PF meter.
Initially,
‘bEnt’
message is displayed on screen.
On pressing the “ ” key, the meter will enter the Bent
function edit mode and user can scroll between yes and no.
YES:
Bent function is enabled
no:
Bent function is disabled
Pressing the “ ” key will accept the displayed condition.
If Bent function is enabled, then the meter will advance to
Input Bent value selection (section 3.1.2.5) otherwise will
exit the Setup menu and return to measurement mode.
3.1.2.5 Input Bent Value (inP.b)
This screen appears only when Bent Function has been enabled. This screen allows
the user to set the Input Bent value. The Bent value can be set in-between
(Input Start value + (1.5% of Input End value)) and 98.5% of Input End value
.
Initially,
‘inP.b’
message is displayed on screen following
which user can start editing Input Bent value by pressing
the “ ” key.
Instead on pressing the “ ” key will confirm the present
value and advance to Display Bent value selection
(section 3.1.2.6).
After entering the edit mode, by pressing the “ ” key user
can turn the
‘-’
symbol On or Off. If
‘-’
symbol is On then
Input Bent value will be set as negative.
Pressing the “ ” key will set the
‘-’
symbol and editing of
first digit will start. By pressing the “ ” key user can scroll
the value from 0 to 9 or it will get restricted depending upon
Input Start and End value.
11