Do not carry a module by wire or Junction box to avoid the hazard of electric shock  and  injury  or any  troubles in a 

module, which it may cause. 

Do  not  drop  anything  on  the  surfaces  of module, to avoid the hazard of    electric shock, injury. 

To avoid the hazard of electric shock and fire, be  sure  that other system components do not cause any hazard of any 

mechanical or electrical nature to the module.Since sparks may be generated, do not install module where flammable 

gases or vapors are present. 

 

 

 

 

 

 
 
Never leave a module unsupported    or unsecured. 

Do  not  drop  module  and  do  not  allow  objects  to  fall  on  module  to  avoid  the  hazard  of  injury  or  any  troubles  in 

modules that it may cause. 

 

 

Do  not  use  or  install  broken  modules  to    avoid the hazard of electric    shock    and injury. 
Do    not    artificially    concentrate on  module  to avoid the  hazard  of fire  or any trouble. 
 
 

 

 

 

 

 

 

 

 

Do  not  touch  the  Junction  box  terminals to avoid the hazard of electric shock and injury. 

Do not change wiring of bypass    diodes to avoid the hazard of electric shock and injury. 

 

CAUTIONS

 

Use   module for    its intended     function only. 

Do not treat the back sheet    and front surface  with  paint  or  adhesives  to  avoid    any troubles. 

 

GENERAL SAFETY

 

Summary of Contents for SYP200S

Page 1: ...this manual is elieved to be reliable but does not constitute an expressed and implied warranty RISEN reserves the right to make changes to the product specifications or manual without prior notice Ge...

Page 2: ...solar cell modules To avoid the hazard of electric shock and injury be sure to ground the modules completely To avoid the hazard of fire and injury do not disassemble the module or remove any part in...

Page 3: ...Never leave a module unsupported or unsecured Do not drop module and do not allow objects to fall on module to avoid the hazard of injury or any troubles in modules that it may cause Do not use or in...

Page 4: ...e Additional devices such as ground fault fuses and disconnects may be required Do not use modules of different configurations in the same system Follow all safety precautions of other used components...

Page 5: ...ever be sealed to the mounting surface with sealant that prevents air from circulating under the module For roof mounted modules the minimum Distance between the roof and the modules should be 5cm 2 i...

Page 6: ...heavy at installation place 4 The sand and dust damages are heavy at installation place 5 Other special conditions with air pollution or with chemically active vapor etc SPECIFICATIONS Notes on speci...

Page 7: ...6PCS 48PCS 72PCS 88PCS Dimens ion mm 1200 550 3 5mm 1080 80 8 35mm 1580 808 35mm 1456 1070 50 mm Note Module complies with the requirements of Electrical protection Class II Rated electrical character...

Page 8: ...uirements or the IEC Note stainless steel washers are used between the ground wire and the module frame see picture 2 The size of grounding hole is 4mm The screw is 5 0mm All washers are with inter di...

Page 9: ...ox has a diagram illustrating the proper direction for the by pass diode to be installed between two of the terminal screws When the solar modules are connected as individual series strings first and...

Page 10: ...NINGHAI RISEN ELECTRIC CO LTD Add Xidian Shaojia Lndustrial Zone Ninghai Ninbo Zhejiang 315613 China Tel 0086 574 65173958 Fax 0086 574 65173959 Website http www risen solar com...

Reviews: