background image

6 - 

FORCE

GB

Assembly instructions - FORCE 825K/825KI

S

A

B

A

A

B

B

C

Use four supplied eyebolts to lift the bollard

See image alongside.

The cable must be recovered while the bollard comes near the foundation
case (ref A). 
Important: In this phase the connector must be free to slide inside of the 
corrugated  sheath.  For  this  reason  is  it  necessary  for  the  segment  be-
tween the bollard and the junction box to be connected by a sheath with 
a diameter of 50 mm, correctly placed, without joints or cross section re-
ductions.

The cable must be gradually released while the bollard descends in the 
case, (Ref. B)

Once  the  insertion  has  been  completed,  the  connector  must  be  in 
proximity of the metal protection (ref C).

Pay attention to the electrical cable, it must be free inside the case housing 
and it must not be crushed. 

Summary of Contents for FORCE 825K

Page 1: ...tallationsanleitung Manuel d installation Manual de instalación Made in Italy RL8542750 Rev 00 GB Crash Tested rising bollard FORCE 825k FORCE825KI successfully passed the crash test and achived a Performance Rating of IWA14 1 2013 Rising Bollard V 2500 N1G 64 90 5 0 ...

Page 2: ...2 FORCE GB Overall Dimentions 340x340 1420x1420 Ø 254 800 1356 810 Ø 305 1237 1 2m ...

Page 3: ...istance to impact and elegant design is suitable for installation in public or commercial areas and is particularly indicated for protecting of buildings The standard version manufactured in steel is painted with electrophoresis painting a corrosion proof treatment that guarantees an extremely elevated resistance to the elements and to salty environments The bollard is operated with 24Vdc an amper...

Page 4: ...1500x1500 MIN B C A MENTO SUTO NON TESSUTO AIA DRENANTE D D CABLE CONNECTOR BOX VERY IMPORTANT CONNEXION PIPELAND D 50 1500 1500 4 0 0 NON WOVEN FABRIC Dig a hole down to 1800mm and introduce approx 30lt of water Insert the foundation case in the excavation Attention The case must rest on the bottom of the excavation and must be perfectly vertical Important In order to make inserting the case easi...

Page 5: ... that is suitable to avoid accidents that may involve per sons or property A sheet metal cover is available as an option Attention The bollard is equipped with a short segment of connec tion cable equipped with a male IP68 connector Different size extension cords are available 5 to 25 m equipped with a female IP68 connector for connecting to the control unit Bring the two parts of the connector to...

Page 6: ... sheath For this reason is it necessary for the segment be tween the bollard and the junction box to be connected by a sheath with a diameter of 50 mm correctly placed without joints or cross section re ductions The cable must be gradually released while the bollard descends in the case Ref B Once the insertion has been completed the connector must be in proximity of the metal protection ref C Pay...

Reviews: