CAUTION:
(As required by the California State Fire
Marshall)
“Early warning fire detection is best achieved by
the installation of fire detection equipment in all
rooms and areas of the household as follows: (1)
A smoke and heat detector installed in each
separate sleeping area (in the vicinity, but
outside of the bedrooms), and (2) Heat or smoke
and heat detectors in the living rooms, dining
rooms, bedrooms, kitchens, hallways, attics,
furnace rooms, closets, utility and, storage
rooms, basements and attached garages.”
For your information, NFPA Standard 74,
Section 2-4 reads as follows:
“2-4.1.1 Smoke and heat detectors shall be
installed outside of each separate sleeping area
in the immediate vicinity of the bedrooms and on
each additional story of the family living unit
including basements and excluding crawl spaces
and unfinished attics.“
The provisions of 2-4.1.1 represent the minimum
number of detectors required by this standard. It
is recommended that the householder consider
the use of additional smoke and heat detectors
for increased protection for those areas
separated by a door from the areas protected by
the required smoke and heat detectors under 2-
4.1.1 above. The recommended additional areas
are living room, dining room, bedroom(s),
kitchen, attic (finished or unfinished), furnace
rooms, utility room, basement, integral or
attached garage, and hallways not included in 2-
4.1.1 above. However, the use of additional
detectors remains the option of the
householder.” We recommend complete
coverage and use of additional smoke and heat
detectors.
Figur 3: Placering av detektorer i
flervåningshus
Figur 4: Rekommendation vid placering i
tak eller på vägg
Figur 5: Rekommendation vid placering i
sluttande tak
VAR DETEKTORER INTE BÖR MONTERAS
Falsklarm inträffar oftast på grund av att detektorer monteras på en plats där de har
svårigheter att fungera på rätt sätt. För att undvika falsklarm ska man undvika att montera
rökdetektorer på följande platser:
♦
Montera inte rökdetektorn där den utsätts för starka luftströmmar. Dessa luftströmmar
kan föra röken vid sidan av detektorn så den inte reagerar. I Figur 6 indikeras
lämpliga respektive olämpliga monteringsplatser gällande detta problem.
♦
I närheten av lösningsmedel som tinner eller liknande.
♦
I direkt närhet av avgassystem från bilar, då dessa kan skada detektorn.