Industrial LuNAR DT AM Grade 3 Installation Guide
14
Selectors and Jumpers
RC/SET
INPUT
Used to determine the polarity of the external inputs.
12V: 12v has to be connected in order activate the function.
GND or N.C. has no influence on the RC/SET status.
(see Relay mode DIP switches configuration)
0V: The GND has to be connected in order to activate the function.
12v or N.C. has no influence on the RC/SET status.
(see Relay mode DIP switches configuration)
EOL
RESISTORS
JUMPERS
FAULT/AM
EOL
JUMPERS
12K
No
Resistor
(Default)
The jumpers are used when connecting the
detector to a DEOL or TEOL Zone. The jumpers
allow the selection of TAMPER, ALARM E.O.L
resistors (1K, 2.2K, 4.7K, 5.6K or 6.8K),
according to the control panel settings. An
additional double jumper allows the connection
of 12K FAULT/AM E.O.L resistor (see EOL
Resistors Schematic).
Follow the terminal block connection diagram
when connecting the detector to a Double/Triple
End Of Line (DEOL/TEOL) Zone.
Schematic of EOL Resistors