background image

Agility User Manual                                                                                                  

 

Page 17 

Acknowledge Menu 

After the Event Announcement message is made, the following list of options is 

announced: 

Operation 

Digit 

Acknowledge Message 

Acknowledging an event means that you have received a message from 

the security alarm system about a relevant event in the system and 
want to confirm this. After you acknowledge an event, the system calls 

the next FM number.  

Press 

[1]

 

Acknowledge and stop all dialing 

This option acknowledges the event and stops the system from calling 

the next FM numbers to report the event. 

Press

 [2]

 

followed by 

the code 

Acknowledge and access the Operations menu 

The 

Operations

 menu lists the available options for remotely operating 

your system. 

Press 

[3]

 

followed by 

the code 

Listen In and Talk 

This option enables you to perform bi-directional communication. 

Press 

[6]

 

followed by 

the code 

Repeat the event message

 

Press 

[#]

 

Repeat the Acknowledge menu 

Press 

[*]

 

Note:

 If an invalid code is entered 3 consecutive times, the system hangs up and this FM number is locked 

for 15 minutes and no calls are initiated to the FM number.  
If a valid user code is not entered within 10 seconds, the system hangs up. 

Bi-directional Communication  

The Listen In and Talk options enable you to remotely and silently listen in to your 
premises in order to verify the cause of an event occurrence, through the microphone or 

remotely talk to your premises via the 

Agility 

loudspeaker, for example, to guide someone 

in distress.  

To listen in or talk: 

1.

 

From the Operations/Acknowledge menu, press 

[6]

. The following messages are 

announced:  

“To Listen In press 1, To Talk press 

[2]

, To Listen and Talk (Open channel) press 

[3], 

To return to the previous menu, Press 

[

Ü

]

.” 

2.

 

Select the desired option.    

3.

 

Press 

[

Ü

to end listening in and talking communication and return to the 

Operations menu. 

Summary of Contents for Agility

Page 1: ...User Manual ...

Page 2: ...nic or mechanical without the express prior written permission of RISCO Group The information contained herein is for the purpose of illustration and reference only Information in this document is subject to change without notice Corporate and individual names and data used in examples herein belong to their respective owners Compliance Statement Hereby RISCO Group declares that the Agility series...

Page 3: ...ing a Panic Alarm 14 Chapter 3 Remote System Operation 15 3 1 Remote Phone Operation 15 Remotely Accessing the System 15 Voice Operations Menu 15 Receiving Calls from the System 16 Acknowledge Menu 17 Bi directional Communication 17 3 2 SMS Operation 18 SMS Remote Control 18 SMS Confirmation Message 19 3 3 Configuration Software 19 3 4 Web Browser 19 Chapter 4 User Functions and Settings 21 4 1 Us...

Page 4: ...Agility User Manual Page 4 ...

Page 5: ...ne using friendly and easy to understand verbal messages as well as SMS or E mail messages This manual describes how to operate your system It will guide you through programming instructions for main system features as well as basic arming and disarming commands for the system 1 1 Main Features 32 wireless zones 1 way or 2 way line detectors 4 optional wired zones only with I O expander 32 User co...

Page 6: ...sensor to detect problems If the panel detects trouble it will notify you with beeps and indicator lights on the panel itself The following diagram shows the components that make up the system 1 3 User Operating Tools The Agility system can be operated using several devices some of which have been designed as bi directional If you have purchased a bi directional device your system is capable of se...

Page 7: ...y Keypad Using the one way keypad you can arm disarm send a panic alarm and activate outputs 4 Button Key fob Using the 4 button key fob you can arm disarm send a panic alarm and activate outputs Remote Phone Operation Using any remote touch tone phone you can perform remote operations such as arming disarming listening in and talking to the premises and more The system can also provide audible in...

Page 8: ...em armed Rapid flash Alarm Slow flash Alarm memory Stay LED Condition Description On System armed at STAY Off System disarmed Ready LED Green Condition Description On System ready Off Open zones Flash Bypassed zones Trouble LED Condition Description Slow flash Trouble Off No trouble Note When all LEDs flash one after another in sequence the system is in Installation mode S O S Status Button The bu...

Page 9: ...ing The GSM GPRS BUS Module can send predefined SMS event messages to a remote Follow Me FM telephone number informing you of the status of the security system and certain events that occurred in the system For example Sound Indications In addition to the visual indications provided by the Agility s LEDs your system produces audible notification after certain events Condition Description Intrusion...

Page 10: ...Agility User Manual Page 10 ...

Page 11: ...ystem is partially armed Partition arming Partition 1 2 3 followed by or One of the Agility s advantages is its ability to divide the system in up to 3 partitions Each partition may be viewed as a separate security system each of which can be armed and disarmed individually regardless of the condition of the other Partitions can be armed or disarmed one at a time or all at once and each partition ...

Page 12: ...he arming operation Note Failing to arm the system will be followed by a local voice message message on the keypad or Led indication on the bi directional remote control 2 2 Disarming your system Disarming your system causes the detectors not to trigger an alarm when violated When you enter the premises the Entry Delay begins to count down You must disarm the system within the Entry Delay time to ...

Page 13: ...icate information regarding the cause of the alarm To disarm using Procedure Press All the partitions assigned to the 2 way remote control code will be disarmed Note If the Quick Disarming option is disabled for the bi directional remote control you must enter the remote control PIN code after pressing the key Press followed by your user code or hold your proximity tag for 2 seconds from a distanc...

Page 14: ...These keys can be either disabled or used to establish a service call to your Monitoring Station Press both and simultaneously for 2 seconds Press the small blank button if defined Note Your installer can define any of the 4 buttons to be used for sending a panic alarm Note For full capabilities of the 2 way remote control the bi directional keypad and 4 button key fob refer to the instructions su...

Page 15: ...l the system picks up After the system picks up a short tone is heard Note When the system picks up all phones on the same line are effectively disconnected and cannot be used 3 Enter your 2 digit remote access code within 10 seconds The following message is announced Hello Please Enter Your User Code Followed By The default 2 digit remote access code is 00 4 Enter your user code followed by 5 Aft...

Page 16: ... Follow Me numbers enabling you a relative or neighbor to be informed of the security situation You can then take the appropriate action whether this is to inform the authorities or acknowledge the event and remotely operate the system Notes Follow Me messages are performed only after reporting to the Monitoring Station Follow Me numbers are assigned certain events for which they receive calls The...

Page 17: ...ional communication Press 6 followed by the code Repeat the event message Press Repeat the Acknowledge menu Press Note If an invalid code is entered 3 consecutive times the system hangs up and this FM number is locked for 15 minutes and no calls are initiated to the FM number If a valid user code is not entered within 10 seconds the system hangs up Bi directional Communication The Listen In and Ta...

Page 18: ...e Agility enables you to perform remote control operations using simple SMS commands The following section describes the SMS commands and the response of the system to these commands Note This application is available only if a GSM GPRS module is installed in your system Operation SMS Message Structure Example Arm all partitions of a user code Code A 1234A Disarm all partitions of a user code Code...

Page 19: ...tion message following an arming operation will be sent to the user Confirmation or Fail operation messages can be assigned to the actions of arming disarming bypassing activating outputs or changing follow me definitions Note For full SMS capabilities refer to your GSM GPRS instruction manual 3 3 Configuration Software You can operate your system via RISCO Groups Configuration Software Refer to y...

Page 20: ...Agility User Manual Page 20 ...

Page 21: ...form many of the Agility functions a security code often called a user code must be used Each individual using the system is assigned a user code which in turn is linked to an Authority Level Those with a higher authority have access to a greater number of system functions while those with a lower authority are more restricted in what they may do There are eight different authority levels availabl...

Page 22: ... confirmation beep is sounded if not 3 quick error beeps are sounded 7 Repeat the above steps for additional codes until you have completed your list 8 When all codes have been entered press quickly to reset and exit the User Functions menu Deleting User Codes At times you may want to completely delete a user code Note that it is impossible to delete the Master Code although it can be changed The ...

Page 23: ...s Tags from the User Functions menu and press 4 Scroll to Proximity Tags and press 5 Select the option New Change Press 6 Enter the two digit User Index number to which you want to assign a tag For example to assign a tag to user index number 6 press Note A display of indicates that a user has already been assigned to a specific proximity tag 7 Within 10 seconds hold the proximity tag at a distanc...

Page 24: ...es 2 Scroll the menu to the option Delete by tag Press 3 Within 10 seconds approach the proximity tag at a distance of 1 to 2 cm from the keypad s keys A confirmation message will be displayed 4 3 Defining Follow Me Destinations In the case of an alarm or event the system can initiate a phone call to a designated telephone or pager send a SMS or send an e mail and employ unique tones or messages t...

Page 25: ...on the FM phone can perform remote listen in and talk operations from the acknowledgment menu N The user on the FM phone cannot perform the listen in and talk operations from the acknowledgment menu 7 If required include the special functions described below to achieve the related effect You can press the or keys to toggle to the required character Function Sequence Results Stop dialing and wait f...

Page 26: ...me and Label Automatic UO Activation A UO home appliance activation program automatically activates and deactivates UOs during your required intervals In each program you can define four UOs to operate simultaneously When defining a UO activation program you need to define the following parameters UOs Time Schedule Vacation and Label Limitation of user Disarming A user limitation program automatic...

Page 27: ... Grand Master User Installer Bypass Zone Provides the ability to bypass any of the system s intrusion zones Bypass zone à Select zone v v Follow Me Define Used to define Follow Me destinations voice message SMS or E mail or to perform a Follow Me test Define à Select FM à Enter Data v v Test FM Used to test Follow Me numbers Test FM à Select FM à Send Message v v Event Log To view a list of system...

Page 28: ...a prepaid SIM card the user has to reset the SIM Expire Time manually The time duration for expiration is defined by your installer v Codes Tags Use this menu to set tags and user codes in the system For detailed information refer to Chapter 4 page 21 v v Clock Time Date à Enter Time à Enter Date Allows the setting of the system time and date This definition is required for setting the scheduler p...

Page 29: ...ring Communication 300mA Backup Battery Sealed Lead Acid Battery 6V 3 3Ah Internal Sounder intensity 90 dBA 1m Operating Temperature 10 C to 40 C 14 F to 104 F Storage temperature 20 C to 60 C 4 F to 140 F Physical Characteristics Dimension HxWxD 268 5 mm x 219 5 mm x 64 mm 10 57 x 8 64 x 2 52 inch Weight No battery 1 31Kg Full configuration GSM module 0 045 Kg Wireless Characteristics RF immunity...

Page 30: ...Notes ...

Page 31: ...Notes ...

Page 32: ...r costs of installation or any liability for direct indirect or consequential damages or delay Seller does not represent that its product may not be compromised or circumvented that the product will prevent any persona injury or property loss by intruder robbery fire or otherwise or that the product will in all cases provide adequate warning or protection Buyer understands that a properly installe...