9
NiMH CHARGE
C=3.0A
Setting Charge Current
Adjust the desired charge current, which ranges from 0.1A to 6.0A with the INC & DEC buttons. Press the ENTER
button to confirm the setting.
NiMH DISCHARGE
D=0.5A 4.8V
Setting Discharge Current
Adjust the desired discharge current, which ranges from 0.1A to 1A with the INC & DEC buttons. Press the ENTER
button to confirm the setting. The current will be automatically limited to maintain 5W maximum.
NiMH DISCHARGE
D=0.5A 4.8V
Setting Discharge Cutoff Voltage
This is the voltage that the charger will stop discharging the battery.
Adjust the total discharge cutoff voltage from 0.1V to 16.8V with the INC & DEC buttons. Press the ENTER button to
confirm the setting.
NiMH CYCLE C->D 5
C=3.0A D=0.5A
Setting Cycle
This is to set cycling with two options (Charge to Discharge / Discharge to Charge). Set cycling with the INC & DEC
buttons, and press the ENTER button to confirm the setting.
NiMH delta-peak-
‘volt = 0mV/cell
Setting Delta Peak Sensitivity
Set the Delta Peak Sensitivity from 3mV to 25mV per cell with the INC & DEC buttons and press the ENTER button to
confirm the setting.